A self-priming, roller-free, miniature, peristaltic pump operable with a single, reciprocating actuator.

نویسندگان

  • Viktor Shkolnikov
  • John Ramunas
  • Juan G Santiago
چکیده

We present a design for a miniature self-priming peristaltic pump actuated with a single linear actuator, and which can be manufactured using conventional materials and methods. The pump is tolerant of bubbles and particles and can pump liquids, foams, and gases. We explore designs actuated by a motor (in depth) and a shape memory alloy (briefly); and briefly present a manually actuated version. The pump consists of a Delrin acetal plastic body with two integrated valves, a flexible silicone tube, and an actuator. Pumping is achieved as the forward motion of the actuator first closes the upstream valve, and then compresses a section of the tube. The increased internal pressure opens a downstream burst valve to expel the fluid. Reduced pressure in the pump tube allows the downstream valve to close, and removal of actuator force allows the upstream valve and pump tube to open, refilling the pump. The motor actuated design offers a linear dependence of flow rate on voltage in the range of 1.75-3 V. Flow rate decreases from 780 μl/min with increasing back pressure up to the maximum back pressure of 48 kPa. At 3 V and minimum back pressure, the pump consumes 90 mW. The shape memory alloy actuated design offers a 5-fold size and 4-fold weight reduction over the motor design, higher maximum back pressure, and substantial insensitivity of flow rate to back pressure at the cost of lower power efficiency and flow rate. The manually actuated version is simpler and appropriate for applications unconstrained by actuation distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-Vitro Red Blood Cells Integrity and Morphology Changes after Passing Through Volumetric Peristaltic Infusion Pump

Background: It is not clear whether the use of volumetric peristaltic infusion pumps, affect the quality of the erythrocytes during packed cell transfusion or not. In the present study in vitro quality of red blood cells was assessed after using this type of infusion pumps in a prospective study. Materials and Methods: In this study 60 units of packed red cells were examined before and after p...

متن کامل

Development of Piezoelectric Gas Micro Pumps with the PDMS Check Valve Design

This paper presents the design and fabrication of a novel piezoelectric actuator for a gas micro pump with check valve having the advantages of miniature size, light weight and low power consumption. The micro pump is designed to have eight major components, namely a stainless steel upper cover layer, a piezoelectric actuator, a stainless steel diaphragm, a PDMS chamber layer, two stainless ste...

متن کامل

A microfluidic reciprocating intracochlear drug delivery system with reservoir and active dose control.

Reciprocating microfluidic drug delivery, as compared to steady or pulsed infusion, has unique features which may be advantageous in many therapeutic applications. We have previously described a device, designed for wearable use in small animal models, that periodically infuses and then withdraws a sub-microliter volume of drug solution to and from the endogenous fluid of the inner ear. This de...

متن کامل

Development of a New Piezoelectrically Actuated Micropump for Liquid and Gas

This paper aims to present the design, fabrication and test of a novel piezoelectric actuated, check-valves embedded micropump having the advantages of miniature size, light weight and low power consumption. This device is designed to pump gases and liquids with the capability of performing the self-priming and bubble-tolerant work mode by maximizing the stroke volume of the membrane as well as...

متن کامل

Hydroelastic Vibration of a Circular Diaphragm in the Fluid Chamber of a Reciprocating Micro Pump

Reciprocating diaphragm micro-pumps are the most common type among indirectly–driven micro-pumps. They operate by reciprocating the diaphragm with associated check valves. This paper addresses the Hydroelastic vibration of circular elastic diaphragm interacting with the incompressible and inviscid liquid inside the cylindrical chamber with a central discharge opening. Taking into account axisym...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sensors and actuators. A, Physical

دوره 160 1-2  شماره 

صفحات  -

تاریخ انتشار 2010