Balloon Valvuloplasty of Tricuspid Stenosis: A Retrospective Study of 5 Labrador Retriever Dogs
نویسندگان
چکیده
BACKGROUND There are limited reports of severe tricuspid valve stenosis in dogs and limited data regarding treatment and outcome. OBJECTIVE To evaluate clinical signs, echocardiographic features, and outcome of balloon valvuloplasty (BV) in dogs with severe tricuspid valve stenosis (TVS) in which BV was attempted. ANIMALS Five client-owned dogs with severe TVS. METHODS Records were retrospectively reviewed and data collected regarding signalment, clinical signs, diagnostic findings, procedures, and outcome. RESULTS All dogs were Labrador Retrievers. Presenting complaints included episodic weakness/syncope (4/5), abdominal distension (4/5), lethargy (2/5), and exercise intolerance (2/5). The median and range of measurements before BV were as follows: TV mean velocity 1.5 m/s (range 1.4-1.7 m/s); velocity-time integral (VTI) 79.8 cm (42.4-99.1 cm); and TV maximum velocity 2.9 m/s (2.3-3.2 m/s). Measurements (available for 3 of 5 dogs) after BV were as follows: TV mean velocity 1.15 m/s (0.9-1.4 m/s); VTI 44.95 cm (41.4-54.8 cm); and TV maximum velocity 1.15 m/s (1.9-2.3 m/s). The procedure was attempted in all dogs and completed in 4/5 dogs. The largest balloon diameter ranged from 15 mm to 25 mm, and length ranged from 4 cm to 5 cm. Right atrial pressure decreased in 4/5 dogs. All but 1 dog had clinical improvement after BV, but recurrence of clinical signs occurred (2/5). Tricuspid regurgitation worsened in 1 dog culminating in right heart failure and euthanasia. CONCLUSIONS AND CLINICAL IMPORTANCE BV can be an effective treatment; however, clinical signs can recur. Right heart failure due to worsened TR is a potential complication in dogs with pre-existing moderate-to-severe TR.
منابع مشابه
Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملبررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی
Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...
متن کاملRestenosis After Balloon Valvuloplasty in Dogs with Congenital Pulmonary Stenosis
The aims of this study were to reveal the prevalence of complications associated with PBV over a long-term follow-up, and to investigate the factors related to those complications, especially pulmonary restenosis. Forty dogs who underwent PBV were retrospectively reviewed. Long-term follow-up was available in 22 dogs. Exacerbation of PI and TR after PBV was observed in some dogs; however, right...
متن کاملImmediate Results of Percutaneous Mitral Balloon Valvuloplasty in Patients with Mitral Stenosis
Introduction: Mitral stenosis is a prevalent valvular disease in developing countries. Percutaneous mitral balloon valvuloplasty (PMBV) is the gold standard treatment. The main objective of this study was to assess the initial results of PMBV in patients with mitral stenosis during 16 years (2002-2018) in Mashhad, Iran. Materials and Methods: From April 2002 to March 2018, 770 patients underwen...
متن کاملEffectiveness of balloon valvuloplasty for stenosis of a bioprosthesis in the tricuspid valve position.
A 67-year-old man underwent percutaneous balloon valvuloplasty for bioprosthetic tricuspid stenosis. He had undergone two tricuspid valve replacements over a period of 39 years and became symptomatic. After the valvuloplasty, his symptoms were resolved. Stenosis of a bioprosthetic tricuspid valve can be successfully and safely treated with balloon valvuloplasty.
متن کامل