Quantification of mitral regurgitation by integrated Doppler backscatter power.

نویسندگان

  • A I MacIsaac
  • I G McDonald
  • K L Kirsner
  • S A Graham
  • R W Gill
چکیده

OBJECTIVES We attempted to determine whether continuous wave Doppler backscatter power could be used to quantify mitral regurgitation. BACKGROUND The power of a Doppler backscatter signal is proportional to the number of scatterers insonated and, hence, to the moving volume of blood. The relative power of the continuous wave Doppler signals from mitral inflow and aortic outflow is therefore proportional to the relative volumes of blood in motion. METHODS Computer postprocessing was used to derive the relative power of the Doppler backscatter signal from the intensity of the pixels within the spectral display of anterograde aortic and mitral flow. The power ratio was used to calculate the regurgitant fraction in 20 patients (mean age 61.4 years) with mitral regurgitation. This Doppler regurgitant fraction was compared with that derived from angiographic left ventricular volume and thermodilution cardiac output. In addition, 12 normal control subjects were studied by the Doppler method. RESULTS Mean (+/- SD) catheterization regurgitant fraction was 0.50 +/- 0.26, and mean Doppler regurgitant fraction was 0.47 +/- 0.25 (r = 0.89). The limits of agreement between the two methods by Bland-Altman analysis were -0.21 + 0.27. In normal control subjects with an expected regurgitant fraction of close to zero, mean Doppler regurgitant fraction was 0.03 +/- 0.05. CONCLUSIONS Doppler backscatter power from mitral and aortic inflow provides a new and accurate method for quantifying mitral regurgitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of pulsed Doppler echocardiography in detection and quantification of aortic and mitral regurgitation.

Pulsed Doppler echocardiography was employed to detect disturbed or turbulent flow diagnostic of aortic or mitral regurgitation. Sensitivity, specificity, diagnostic accuracy, and predictive value were assessed by the independent interpretation and comparison of aortic root angiograms (91 patients) and left ventriculograms (94 patients) to the time interval histogram display of the pulsed Doppl...

متن کامل

Determination of regurgitant fraction in isolated mitral or aortic regurgitation by pulsed Doppler two-dimensional echocardiography.

Measurements of mitral and aortic valve flows were obtained with two-dimensional Doppler echocardiography in 25 patients with isolated mitral (n = 19) or aortic (n = 6) regurgitation and regurgitant fraction was calculated as the difference between the two flows divided by the flow through the regurgitant valve. Results were compared with measurements of regurgitant fraction determined by combi...

متن کامل

Detection and estimation of the degree of mitral regurgitation by range-gated pulsed doppler echocardiography.

Sensitivity and specificity of detection of mitral regurgitation was assessed by range-gated Doppler echocardiography. The degree of mitral regurgitation was also estimated by the depth and width of the regurgitant jet detected with Doppler and compared with that assessed by left ventriculography. Of 47 patients with an adequate Doppler study, 24 had no mitral regurgitation by ventriculography....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 1994