Evaluation of the Fractured Surface of Five Endodontic Rotary Instruments: A Metallurgical Study
نویسندگان
چکیده
INTRODUCTION The aim of this study was to compare several metallurgic properties of Neoniti instrument with four other commonly used endodontic rotary files. METHODS AND MATERIALS Neoniti A1 (25/0.08), RaCe (25/0.06), Mtwo (25/0.06), Twisted file (25/0.06) and ProTaper Next X2 (25/0.06) were examined by differential scanning calorimetry (DSC) before and after heat treatment at 500°C. X-ray diffraction (XRD) was also performed on the specimens. Furthermore, scanning electron microscopy (SEM) and x-ray energy-dispersive spectrometric (EDS) analyses were carried out on randomly selected fractured files. RESULTS In SEM tests, dimpled ruptures, characteristic of ductile fracture, were seen in all evaluated cross sections of all files. The SEM results of all evaluated files were alike. EDS results revealed higher proportions of Nickel (Ni) rich intermetallic compounds in Neoniti; whereas, in all the other files the proportion of Titanium (Ti) rich precipitates was higher. DSC results indicated that the temperature present in the oral environment, the austenite phase existed in all files. Mtwo and RaCe files did not show austenite transformation in the temperature range evaluated in this study. Only Neoniti revealed rhombohedal phase (R-phase) transformation. After heat treatment. No significant difference was seen in the transformation temperatures of all evaluated files. XRD evaluations revealed that Neoniti contained both Ni-rich and Ti-rich precipitates. The amount of the martensite phase was higher in ProTaper Next. CONCLUSION The metallurgic properties of Neoniti files were different from other evaluated rotary files. This file contained higher proportions of Ni-rich precipitates.
منابع مشابه
Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals
Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...
متن کاملApplication of nondestructive testing in cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments.
The purpose of this study was to investigate the application of nondestructive testing in cyclic fatigue evaluation of endodontic ProFile nickel-titanium (NiTi) rotary instruments. As-received ProFile instruments were made to rotate freely in sloped metal blocks by a contra-angle handpiece mounted on a testing machine. Rotation was interrupted periodically, and the instrument removed and engage...
متن کاملEvaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: clinical cases.
The removal of fractured rotary nickel-titanium instruments from small, curved root canals is one of the most complex operative procedures in endodontics. There have been many different devices and techniques developed to remove fractured instruments, but none are consistently successful and all show a high incidence of canal damage such as perforation. A technique using a staging platform and ...
متن کاملA comparative study of the cleaning effect of various ultrasonic cleaners on new, unused endodontic instruments
BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...
متن کاملTips to avoid instrument separation in endodontics.
procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...
متن کامل