Phantom studies and clinical application of high resolution, image reconstruction using (18)F-fluoromethylcholine PET/CT for prostate cancer.
نویسندگان
چکیده
The aim of this study is to evaluate the impact of a high resolution (HR) image reconstruction with a voxel size of 2mm in comparison to the most routinely used standard reconstruction with 4mm voxels in patients suffering from prostate cancer having undergone (18)F-methylcholine PET/CT. Phantom studies were performed using a Jaszczak phantom and a custom made phantom containing small hot lesions (size 2-10mm). Clinical evaluation was performed on PET/CT scans of 50 patients. Images were reconstructed with 4mm and 2mm voxel size and analyzed quantitatively using AMIDE and MATLAB. Clinical images were judged by two observers concerning TNM staging, image quality and the correlation of PET and CT data. Phantom studies revealed increased SUVmean and SUVmax values in the HR images (P<0.01). The lower detection limit was approximately 3mm in the HR and 4-5mm in the conventional images. Lower FWHM values were found in the HR images. No significant difference was found concerning the image quality and the correlation of PET and CT (each P>0.5). For both reconstructions, a comparable total amount of lesions was reported (P>0.5) with no impact on the TNM staging. In conclusion, the HR PET reconstruction provides semi-quantitative advantages in the sense of an improved lower detection limit and increased semi-quantitative tumour-to-background ratios. In the setting of choline PET/CT for prostate cancer the high resolution reconstruction could be implemented clinically as there are no relevant qualitative differences between this and the conventional image resolution in terms of image quality, assessment confidence and lesion identification rate.
منابع مشابه
Improved Image Fusion in PET/CT Using Hybrid Image Reconstruction and Super-Resolution
PURPOSE To provide PET/CT image fusion with an improved PET resolution and better contrast ratios than standard reconstructions. METHOD Using a super-resolution algorithm, several PET acquisitions were combined to improve the resolution. In addition, functional PET data was smoothed with a hybrid computed tomography algorithm (HCT), in which anatomical edge information taken from the CT was e...
متن کاملRole of 18F-choline PET/CT in evaluation of patients with prostate carcinoma
BACKGROUND Choline presents a high affinity for malignant prostate tissue. It can be labelled with positron emitting (18)F, and used for the evaluation of patients with prostate carcinoma by PET/CT imaging. The aim of this paper is to summarise our experience with fluoromethylcholine ((18)F-choline) PET/CT in patients with prostate cancer. METHODS In 4 months we investigated the patients with...
متن کامل18F-Choline PET/MRI: The Additional Value of PET for MRI-Guided Transrectal Prostate Biopsies.
UNLABELLED We assessed the value of fusion (18)F-fluoromethylcholine ((18)F-choline) PET/MRI for image-guided (targeted) prostate biopsies to detect significant prostate cancer (Gleason ≥ 3 + 4) compared with standard (systematic 12-core) biopsies. METHODS Within an ongoing prospective clinical trial, hybrid (18)F-choline PET/CT and multiparametric 3T MRI (mpMRI) of the pelvis were performed ...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملAccuracy and Precision of Partial-Volume Correction in Oncological PET/CT Studies.
Accurate quantification of tracer uptake in small tumors using PET is hampered by the partial-volume effect as well as by the method of volume-of-interest (VOI) delineation. This study aimed to investigate the effect of partial-volume correction (PVC) combined with several VOI methods on the accuracy and precision of quantitative PET. METHODS Four image-based PVC methods and resolution modeli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of nuclear medicine
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2014