Myocardial resistance assessed by guidewire-based pressure-temperature measurement: in vitro validation.

نویسندگان

  • Wilbert Aarnoudse
  • Petra van den Berg
  • Frans van de Vosse
  • Maartje Geven
  • Marcel Rutten
  • Mark Van Turnhout
  • William Fearon
  • Bernard de Bruyne
  • Nico Pijls
چکیده

By injecting a few cubic centimeters of saline into the coronary artery and using thermodilution principles, mean transit time (T(mn)) of the injectate can be calculated and is inversely proportional to coronary blood flow. Because microvascular resistance equals distal coronary pressure (P(d)) divided by myocardial flow, the product P(d). T(mn) provides an index of myocardial resistance (IMR). In this in vitro study in a physiologic model of the coronary circulation, we compared IMR to true myocardial resistance (TMR) at different degrees of myocardial resistance and at different degrees of epicardial stenosis. Absolute blood flow was varied from 42 to 203 ml/min and TMR varied from 0.39 to 1.63 dynes. sec/cm(5). Inverse mean transit time correlated well to absolute blood flow (R(2) = 0.93). Furthermore, an excellent correlation was found between IMR and TMR (R(2) = 0.94). IMR was independent on the severity of epicardial stenosis and thus specific for myocardial resistance. Thus, using one single guidewire, both fractional flow reserve and IMR can be measured simultaneously as indexes of epicardial and microvascular disease, respectively, enabling separate assessment of both coronary arterial and microvascular disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary thermodilution to assess flow reserve: experimental validation.

BACKGROUND Fractional flow reserve (FFR) and coronary flow reserve (CFR) are indices of coronary stenosis severity that provide the clinician with complementary information on the contribution of epicardial arteries and microcirculation to total resistance to myocardial blood flow. At present, FFR and CFR can only be obtained by 2 separate guidewires. The present study tested the validity of th...

متن کامل

Safety of guidewire-based measurement of fractional flow reserve and the index of microvascular resistance using intravenous adenosine in patients with acute or recent myocardial infarction.

AIMS Coronary guidewire-based diagnostic assessments with hyperemia may cause iatrogenic complications. We assessed the safety of guidewire-based measurement of coronary physiology, using intravenous adenosine, in patients with an acute coronary syndrome. METHODS We prospectively enrolled invasively managed STEMI and NSTEMI patients in two simultaneously conducted studies in 6 centers (NCT017...

متن کامل

Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity.

The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gra...

متن کامل

Development and validation of a short form of the self-efficacy measurement tool for Iranian patients with myocardial infarction

To assess efficacy in patients with heart failure need to have a scientific tool based on psychometric features is evident. The researchers developed a scientific tool based on psychometric principles for assessing self-efficacy beliefs in patients with Myocardial Infarction (MI) as the only tool of its kind; however, Due to the large number of questions in the questionnaire, respondents may no...

متن کامل

Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study

BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2004