Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization.

نویسندگان

  • Vivek Muthurangu
  • David Atkinson
  • Maxime Sermesant
  • Marc E Miquel
  • Sanjeet Hegde
  • Robert Johnson
  • Rado Andriantsimiavona
  • Andrew M Taylor
  • Edward Baker
  • Robert Tulloh
  • Derek Hill
  • Reza S Razavi
چکیده

Pulmonary hypertensive disease is assessed by quantification of pulmonary vascular resistance. Pulmonary total arterial compliance is also an indicator of pulmonary hypertensive disease. However, because of difficulties in measuring compliance, it is rarely used. We describe a method of measuring pulmonary arterial compliance utilizing magnetic resonance (MR) flow data and invasive pressure measurements. Seventeen patients with suspected pulmonary hypertension or congenital heart disease requiring preoperative assessment underwent MR-guided cardiac catheterization. Invasive manometry was used to measure pulmonary arterial pressure, and phase-contrast MR was used to measure flow at baseline and at 20 ppm nitric oxide (NO). Total arterial compliance was calculated using the pulse pressure method (parameter optimization of the 2-element windkessel model) and the ratio of stroke volume to pulse pressure. There was good agreement between the two estimates of compliance (r = 0.98, P < 0.001). However, there was a systematic bias between the ratio of stroke volume to pulse pressure and the pulse pressure method (bias = 61%, upper level of agreement = 84%, lower level of agreement = 38%). In response to 20 ppm NO, there was a statistically significant fall in resistance, systolic pressure, and pulse pressure. In seven patients, total arterial compliance increased >10% in response to 20 ppm NO. As a population, the increase did not reach statistical significance. There was an inverse relation between compliance and resistance (r = 0.89, P < 0.001) and between compliance and mean pulmonary arterial pressure (r = 0.72, P < 0.001). We have demonstrated the feasibility of quantifying total arterial compliance using an MR method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovative Methodology Measurement of total pulmonary arterial compliance using invasive pressure monitoring and MR flow quantification during MR-guided cardiac catheterization

Vivek Muthurangu, David Atkinson, Maxime Sermesant, Marc E. Miquel, Sanjeet Hegde, Robert Johnson, Rado Andriantsimiavona, Andrew M. Taylor, Edward Baker, Robert Tulloh, Derek Hill, and Reza S. Razavi Cardiac MR Research Group, Division of Imaging Sciences, King’s College London; Department of Congenital Heart Disease, Guy’s Hospital; and Cardiothoracic Unit, Institute of Child Health and Great...

متن کامل

MR phase-contrast imaging in pulmonary hypertension

Pulmonary hypertension (PH) is a life-threatening, multifactorial pathophysiological haemodynamic condition, diagnosed when the mean pulmonary arterial pressure equals or exceeds 25 mmHg at rest during right heart catheterization. Cardiac MRI, in general, and MR phase-contrast (PC) imaging, in particular, have emerged as potential techniques for the standardized assessment of cardiovascular fun...

متن کامل

Magnetic resonance--guided cardiac catheterization in a swine model of atrial septal defect.

BACKGROUND Radiation exposure during cardiac catheterization, limited image planes, and poor soft tissue definition are disadvantages of x-ray fluoroscopy that could be overcome with the use of MRI. This study evaluates the feasibility of real-time MRI (MR fluoroscopy) to guide left and right heart catheterization. METHODS AND RESULTS Anesthetized pigs (n=7) with defects of the atrial septum ...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Pulmonary arterial compliance: How and why should we measure it?

The pulmonary circulation is a high-flow/low-pressure system, coupled with a flow generator chamber-the right ventricle-, which is relatively unable to tolerate increases in afterload. A right heart catheterization, using a fluid-filled, balloon-tipped Swan-Ganz catheter allows the measurement of all hemodynamic parameters characterizing the pulmonary circulation: the inflow pressure, an accept...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 289 3  شماره 

صفحات  -

تاریخ انتشار 2005