Using the MDCT thick slab MinIP method for the follow-up of pulmonary emphysema.

نویسندگان

  • Hai Lan
  • Hiromu Nishitani
  • Sadamitsu Nishihara
  • Junji Ueno
  • Shoichiro Takao
  • Seiji Iwamoto
  • Takashi Kawanaka
  • Mawlan Mahmut
  • Si Qingge
چکیده

PURPOSE The purpose of this study was to evaluate the usefulness of thick slab minimum intensity projection (MinIP) as a follow-up method in patients with pulmonary emphysema. This method was used to determine the presence or absence of changes over time in the lung field based on multi-detector-row CT (MDCT) data. METHODS Among patients diagnosed with pulmonary emphysema who underwent 16-MDCT (slice thickness, 1 mm) twice at an interval of 6 months or more, 12 patients without changes in the lung field and 14 with clear changes in the lung field were selected as subjects. An image interpretation experiment was performed by five image interpreters. Pulmonary emphysema was followed up using two types of thick slab MinIP (thick slab MinIP 1 and 2) and multi-planar reformation (MPR), and the results of image interpretation were evaluated by receiver operating characteristic (ROC) analysis. In addition, the time required for image interpretation was compared among the three follow-up methods. RESULTS The area under the ROC curve (Az) was 0.794 for thick slab MinIP 1, 0.778 for the thick slab MinIP 2, and 0.759 for MPR, showing no significant differences among the three methods. Individual differences in each item were significantly more marked for MPR than for thick slab MinIP. The time required for image interpretation was around 18 seconds for thick slab MinIP 1, 11 seconds for thick slab MinIP 2, and approximately 127 seconds for MPR, showing significant differences among the three methods. CONCLUSION There were no significant differences in the results of image interpretation regarding the presence or absence of changes in the lung fields between thick slab MinIP and MPR. However, thick slab MinIP showed a shorter image interpretation time and smaller individual differences in the results among image interpreters than MPR, suggesting the usefulness of this method for determining the presence or absence of changes with time in the lung fields of patients with pulmonary emphysema.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Massive Emphysema and Pneumothorax Following Shoulder Arthroscopy under General Anaesthesia: A Case Report

The patient was a 61-year-old female with massive rotator cuff tear who had no history of smoking, COPD, asthma, or other pulmonary diseases. Four hours following shoulder arthroscopy, the patient developed progressive dyspnea, which was diagnosed as pneumothorax with subcutaneous emphysema extending to the neck and face. Chest tube was inserted promptly. The patient was discharged with a good ...

متن کامل

Multidetector Computed Tomography (MDCT) Score and Pulmonary Function Tests in Determining Severity of Bronchiectasis

Objective: To determine the severity score of bronchiectasis using MDCT and pulmonary function tests and to relate the extent of MDCT score to pulmonary function tests. Patients and Methods: A prospective study was performed in Assuit University Hospitals from 2011 to 2013 and it included 50 patients underwent MDCT examination and pulmonary function. Two radiologists interpreted MDCT images acc...

متن کامل

Longitudinal changes in structural abnormalities using MDCT in COPD: do the CT measurements of airway wall thickness and small pulmonary vessels change in parallel with emphysematous progression?

BACKGROUND Recent advances in multidetector computed tomography (MDCT) facilitate acquiring important clinical information for managing patients with COPD. MDCT can detect the loss of lung tissue associated with emphysema as a low-attenuation area (LAA) and the thickness of airways as the wall area percentage (WA%). The percentage of small pulmonary vessels <5 mm2 (% cross-sectional area [CSA] ...

متن کامل

Variation of Densitometry on Computed Tomography in COPD – Influence of Different Software Tools

OBJECTIVES Quantitative multidetector computed tomography (MDCT) as a potential biomarker is increasingly used for severity assessment of emphysema in chronic obstructive pulmonary disease (COPD). Aim of this study was to evaluate the user-independent measurement variability between five different fully-automatic densitometry software tools. MATERIAL AND METHODS MDCT and full-body plethysmogr...

متن کامل

Diagnosis of Annular Pancreas Using Minimum Intensity Projection of Multidetector Row CT: Case Report

the pancreas in which a section of pancreatic tissue completely or partially encircles the second portion of duodenum, and the anatomical anomaly frequently results in varying degrees of duodenal obstruction (1). About half of all patients with annular pancreas present with their initial symptoms in adulthood (2). Symptomatic cases should be surgically treated, but the diagnosis of annular panc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of medical investigation : JMI

دوره 58 3-4  شماره 

صفحات  -

تاریخ انتشار 2011