Partition coefficients of some acetate esters and alcohols in water, blood, olive oil, and rat tissues.

نویسندگان

  • T Kaneko
  • P Y Wang
  • A Sato
چکیده

Partition coefficients of hydrophilic organic solvents (C1-C5 acetate esters and alcohols) in distilled water, olive oil, human blood, and various rat tissues (blood, liver, kidney, brain, muscle, and fat) were determined. Water/air partition coefficients were measured by a new vial equilibration technique, which needs no direct measurement of the concentration in either the liquid phase or the gas phase, but only the gas chromatographic peak areas from both phases. Once the water/air partition coefficients had been measured, the blood/air, oil/air, and tissue/air partition coefficients could be measured by the previously developed vial equilibration method, which uses gas chromatographic peak areas from the gas phases in the sample (which contains test material) and the reference (which contains no test material) vessels. The alcohols tested were 32 (methanol) to 128 (n-pentanol) times more hydrophilic than the corresponding esters compared with oil/water partition coefficients. In general, water/air partition coefficients decreased and oil/air partition coefficients increased in proportion to the number of carbon atoms. Blood/air coefficients of alcohols were almost parallel to water/air partition coefficients, whereas no such relation was found with acetate esters. n-Isomers of both acetate esters and alcohols were found to be more soluble in water, blood, oil, and tissues than the corresponding iso-isomers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of gas-to-olive oil partition coefficients of organic compounds using an artificial neural network.

The main aim of the present work was development of a quantitative structure-property relationship method using an artificial neural network (ANN) for predicting gas-to-olive oil partition coefficients of organic compounds. As a first step, a multiple linear regression (MLR) model was developed; the descriptors appearing in this model were considered as inputs for the ANN. These descriptors are...

متن کامل

Partition coefficients of low-molecular-weight volatile chemicals in various liquids and tissues.

Partition coefficients are required for developing physiologically based pharmacokinetic models used to assess the uptake, distribution, tabolism, and elimination of volatile chemicals in mammals. A gas-phase vial equilibration technique is presented for determining the liquid:air and tissue:air partition coefficients for low-molecular-weight volatile chemicals. This technique was developed fro...

متن کامل

Liquid/air partition coefficients of four terpenes.

The liquid/air partition coefficients of four common terpenes, alpha-pinene, beta-pinene, 3-carene, and limonene, have been determined in vitro using head space technique. The liquids used were water, human blood, and olive oil. alpha-Pinene, beta-pinene, and 3-carene were practically insoluble in water and limonene was slightly soluble; all were readily dissolved in olive oil. The oil/air part...

متن کامل

Intrarenal volumes of distribution and relative diffusion coefficients of monohydric alcohols.

Indicator dilution outflow patterns in renal venous blood from anesthetized dog kidney were measured for the monohydric alcohols from methanol to hexanol with tritiated water (THO) and T-1824 dye as reference indicators. Also measured were olive-oil-to-water and red-cell-to-plasma partition coefficients. The indicator dilution results were: (1) at normal hematocrit, the mean transit times of al...

متن کامل

Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods

Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 51 1  شماره 

صفحات  -

تاریخ انتشار 1994