Evaluation of interaction between a spinal cord stimulator and implanted cardioverter-defibrillator in a swine model.
نویسندگان
چکیده
BACKGROUND Spinal cord stimulators (SCS) have been used for many years to treat a myriad of chronic pain conditions using electrical signals to diminish the perception of a painful stimulus. Because of the electrical nature of the devices, there is a concern about the potential for electromagnetic interaction between the device and lifesaving cardiac implantable cardioverters-defibrillators (ICVD). OBJECTIVE The purpose of this study was to use a swine model to evaluate the potential for interaction between an implanted SCS and ICVD using the closest possible proximity, highest stimulation settings, and most sensitive ICVD settings. METHODS A pig was anesthetized and subsequently an ICVD and ICVD lead (Cogni 100-D and Endotak Reliance®, Boston Scientific, Natick, MA) were placed into the right prepectoral region and the right ventricle, respectively. An SCS (50 cm linear ST Precision Plu octad electrode lead [Boston Scientific, Valencia, CA] with 3 mm wide contacts spaced one mm apart- ) was implanted using fluoroscopic guidance into the posterior epidural space. Remote interrogation and programming of the ICVD were performed while the SCS lead was placed in as close proximity as possible, using fluoroscopy to guide the final position of the SCS electrode. After confirming that both systems were working, appropriately 9 stimulating configurations of varying current, pulse width, and frequency, including maximal settings, were delivered through the SCS. The effects on the ICVD were recorded at 2 sensitivity settings. RESULTS None of the tested SCS configurations caused interference with the proper functioning of the ICVD. LIMITATIONS The anatomical proximity of the posterior epidural space and right ventricle of the swine is different from humans. While the entire pacer, including generator, was imbedded in a subcutaneous pocket, an implantable pulse generator for the SCS was not implanted, which did not allow us to study if any damage or a resetting of settings had occurred to the generator. Only one manufacturer was used in this study. Also, this study was performed in an anesthetized pig and the anatomical positions remained static. Realistically, changes in position of the devices would occur in patients who perform activities of daily living, and this can potentially shorten the distance between the 2 leads causing adverse interaction. CONCLUSION This study clearly demonstrated the feasibility of the 2 devices coexisting and functioning appropriately in an animal model using an ICVD and SCS donated by Boston Scientific. Further studies are needed to elucidate restrictions, optimal settings and parameters in a human setting.
منابع مشابه
Spinal cord stimulation for refractory angina in patients implanted with cardioverter defibrillators: five case reports.
Patients implanted with a cardioverter defibrillator (ICD) who are suffering from refractory angina pectoris could benefit from spinal cord stimulation (SCS) due to the well-documented pain relieving effect. However, the combined treatment remains controversial. The aim of the study is to report successful long-term treatment with SCS in five patients implanted with cardioverter defibrillators....
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملA Case Report On Compatibility of Electronic Implants: Spinal Cord Stimulator and Cochlear Implant
Objective: We report the case of a patient with a previously implanted spinal cord stimulator (SCS) who presented for a cochlear implant. The patient was successfully implanted with a Nucleus CI422 Slim Straight Electrode from Cochlear Company. Methods: The authors conducted a case report and literature review. Results: Successful hookup and mapping of the device was performed 1 month and 6 mon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pain physician
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2013