Iodine Concentration and Optimization in Computed Tomography Angiography: Current Issues.

نویسندگان

  • Lorenzo Faggioni
  • Michela Gabelloni
چکیده

Computed tomography (CT) technology has seen a dramatic evolution in the recent past that has deeply changed the face of this diagnostic modality. Since the early days of helical single-slice and then multislice CT, CT angiography (CTA) has been one of the most technically demanding applications, both in terms of scanning technique and contrast medium (CM) injection protocol, due to the need to acquire a large amount of high-resolution data over a limited period corresponding to the peak contrast enhancement of the arterial system. Iodine concentration is one of the main determinants of arterial enhancement in CTA, and current low-osmolar and iso-osmolar nonionic CM for intravascular administration still come in a handful of molecules, but a relatively wide range of different iodine concentrations. This gives the opportunity to optimize CTA protocols as a function of several factors such as patient characteristics, CT technology, and CM features in an attempt to maximize the diagnostic yield of CTA examinations while considering patient safety and avoiding unnecessary extra costs. Our aim is to provide an up-to-date overview of the existing evidence on how changing iodine concentration can have an impact on CTA performance, especially with the use of state-of-the-art CT and power injector technology, in the perspective of improving patient care while minimizing overall exposure to iodinated CM and ionizing radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans

Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial

BACKGROUND With the development of computed tomography (CT) technology, coronary CT angiography can be acquired with low doses of radiation and contrast agent without a loss of diagnostic performance. The primary objective of the CONCENTRATE study is to prove the noninferiority of the enhancement effect of low-concentration contrast agents compared to a high-concentration contrast agent of the ...

متن کامل

High-Pitch, Low-Voltage and Low-Iodine-Concentration CT Angiography of Aorta: Assessment of Image Quality and Radiation Dose with Iterative Reconstruction

OBJECTIVE To assess the image quality of aorta obtained by dual-source computed tomography angiography (DSCTA), performed with high pitch, low tube voltage, and low iodine concentration contrast medium (CM) with images reconstructed using iterative reconstruction (IR). METHODS One hundred patients randomly allocated to receive one of two types of CM underwent DSCTA with the electrocardiogram-...

متن کامل

Low-Dose Scanning Technology Combined with Low-Concentration Contrast Material in Renal Computed Tomography Angiography (CTA): A Preliminary Study

BACKGROUND This study is to investigate the feasibility of low iodine concentration contrast material (CM) combined with low tube voltage and adaptive statistical iterative reconstruction (ASIR) in renal computed tomography angiography (CTA). MATERIAL AND METHODS A total of 136 patients were enrolled in this prospective trial, and randomly divided into two groups: group A (n=68) and group B (n=...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 51 12  شماره 

صفحات  -

تاریخ انتشار 2016