Stent underexpansion in angiographic guided percutaneous coronary intervention, despite adjunctive balloon post-dilatation, in drug eluting stent era

نویسندگان

  • Mehrdad Taherioun
  • Mohammad Hassan Namazi
  • Morteza Safi
  • Habibolah Saadat
  • Hossein Vakili
  • Saeed Alipour-Parsa
  • Hasan Rajabi-Moghadam
  • Shamsedin Pedari
چکیده

BACKGROUND Stent underexpansion is the most powerful predictor of long-term stent patency and clinical outcome. The purpose of this study was to evaluate the incidence and predictors of stent underexpansion despite adjunctive post-dilatation with non-compliant balloon. METHODS After elective coronary stent implantation and adjunctive post-dilatation with non-compliant balloon and optimal angiographic result confirmed by the operator, intravascular ultrasound (IVUS) was performed for all the treated lesions. If the treated lesions fulfilled the IVUS criteria, they are considered as the optimal stent group; if not, they are considered as the suboptimal group. RESULTS From 50 patients enrolled in this study 39 (78%) had optimal stent deployment and 11 (22%) had suboptimal stent deployment. In the suboptimal group 7 (14%) had underexpansion, 2 (4%) malposition, and 2 (4%) had asymmetry. There were no stent edge dissections detected by IVUS. We did not find any correlation between lesion calcification, ostial lesions, stent length, and stent underexpansion. Stent diameter ≤ 2.75 mm had a strong correlation with stent underexpansion. CONCLUSION Despite adjunctive post-dilatation with noncompliant balloon, using a relatively small stent diameter was a strong predictor for underexpansion. IVUS guided percutaneous coronary intervention (PCI) may be considered for drug eluting stent (DES) implantation in relatively small vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stent Optimization Using Adjunctive Balloon Dilatation in the Era of Second-Generation Drug-Eluting Stents

Percutaneous coronary intervention (PCI) using both balloon angioplasty and coronary stents has markedly reduced adverse cardiac events in patients with ischemic heart disease. Drug-eluting stents (DES) could further decrease the incidence of target vessel revascularization (TVR) to 5%–10% compared to bare-metal stents (BMS) or balloon angioplasty alone.1) Despite its clinical benefits, stent f...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled

The use of intravascular ultrasound (IVUS) to improve acute angiographic results was already shown in the prestent era. Various studies demonstrated the efficacy of IVUS in balloon sizing and estimating the extent of positive remodeling. With the introduction of drug-eluting stents (DES) the rate of restenosis has been significantly reduced but a new concern, the risk of stent thrombosis, has e...

متن کامل

Post-sirolimus-eluting stent restenosis treated with repeat percutaneous intervention: late angiographic and clinical outcomes.

BACKGROUND We evaluated the clinical and angiographic outcomes of patients presenting with restenosis after sirolimus-eluting stent (SES) implantation treated with repeated percutaneous intervention. METHODS AND RESULTS A total of 24 consecutive patients have undergone repeated percutaneous intervention to treat post-SES restenosis (27 lesions). The restenosis was located within the stent in ...

متن کامل

Optical coherence tomography findings after longitudinal ablation for an underexpanded stent in a heavily calcified lesion: a case report

BACKGROUND Heavy coronary artery calcification is responsible for stent underexpansion, which is associated with increased in-stent restenosis. Here we report a case in which optical coherence tomography (OCT) demonstrated that the metal component of an underexpanded stent previously implanted in a heavy calcified lesion had been completely removed after ablation with rotational atherectomy. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2014