The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion

نویسندگان

  • Simon J. Otter
  • Brunilda Agalliu
  • Nicola Baer
  • Georgie Hales
  • Katrina Harvey
  • Keeley James
  • Richard Keating
  • Warren McConnell
  • Rachel Nelson
  • Saddaf Qureshi
  • Steven Ryan
  • Abigail St. John
  • Heather Waddington
  • Katie Warren
  • Duane Wong
چکیده

BACKGROUND Adequate sagittal plane motion of the first metatarsalphalangeal joint (1st MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool. We aimed to determine the intra and inter-rater reliability together with the concurrent validity of a universal plastic goniometer (UG) and a smartphone applicationlication (Dr G) for the measurement of dorsiflexion at the 1st MTPJ. METHODS Measurement of joint position and passive range of motion of the 1st MTPJ dorsiflexion was compared using a UG and DrG goniometer. A double-blind repeated measures design was utilized, with intraclass correlation coefficient (ICC) used to determine levels of reliability. RESULTS For joint position good intra-rater reliability (ICC >0.861) and good inter-rater reliability (ICC >0.823) was noted. However, the Dr G application consistently measured lower angles (mean 27.8° (SD 8.37)) than the UG (mean 32° (SD 11.7)) and these associations were significant (r = 0.399, p < 0.001). For passive range of motion, the mean total range of dorsiflexion motion (from maximum plantarflexed position to maximum dorsiflexed position) was 82.8° (SD 12.2) for the UG and 82.9° (SD 11.3) for the Dr G application. Both instruments demonstrated high levels of intra-rater reliability (ICC >0.809). Inter-rater reliability was moderate to good for the UG (ICC 0.693 (95 % CI 0.580 to 0.788)) and good for the Dr G application (ICC 0.708 (95 % CI 0.597 to 0.799)). CONCLUSIONS Moderate to high intra and inter-rater reliability of joint position and passive 1st MTPJ motion can be achieved with traditional and smartphone-based goniometric measurement. The Dr G application may provide a slightly higher reliability, but devices should not be used inter-changeably as significant variation in measurement between devices may occur.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of a smartphone goniometer app compared with traditional goniometer for measuring passive motion at the first metatarsophalangeal joint

Background Adequate sagittal plane motion of the first metatarsalphalangeal joint (1 MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool for 1 MTPJ pathology. We aimed to determine the intra and interrater reliability of a universal plastic goniometer and a smartphone application when measuring dorsiflexion at the 1 MTPJ.

متن کامل

Effect of foot posture and inverted foot orthoses on hallux dorsiflexion.

A pronated foot posture is considered to be a factor in limitation of dorsiflexion at the first metatarsophalangeal joint during weightbearing. Customized foot orthoses are widely used to increase dorsiflexion at the first metatarsophalangeal joint in people with pronated feet. However, the effect of foot posture and customized foot orthoses on maximum first metatarsophalangeal joint dorsiflexi...

متن کامل

Validation of a novel smartphone accelerometer-based knee goniometer.

Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventi...

متن کامل

Assessment of novel digital and smartphone goniometers for measurement of canine stifle joint angles.

OBJECTIVE To evaluate accuracy and reliability of 3 novel goniometers for measurement of canine stifle joint angles and compare the results with those obtained with a universal goniometer (UG). SAMPLE 8 pelvic limbs from 4 canine cadavers. PROCEDURES Each limb was secured to a wooden platform at 3 arbitrarily selected fixed stifle joint angles. Goniometry was performed with 2 smartphone-based a...

متن کامل

Reliability of ankle dorsiflexion passive range of motion measurements obtained using a hand-held goniometer and Biodex dynamometer in stroke patients

[Purpose] This study investigated the reliability of ankle dorsiflexion passive range of motion (DF-PROM) measurements obtained using a goniometer and Biodex dynamometer in stroke patients. [Subjects] Fifteen stroke patients participated in this study. [Methods] Ankle DF-PROM was assessed using a goniometer and Biodex dynamometer. Ankle DF-PROM was measured during two sessions with 7 days betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015