Easily constructed spectroelectrochemical cell for batch and flow injection analyses.
نویسندگان
چکیده
The design and performance of an easily constructed spectroelectrochemical cell suitable for batch and flow injection measurements are described. The cell is fabricated from a commercially available 5-mm quartz cuvette and employs 60 ppi reticulated vitreous carbon as the working electrode, resulting in a reasonable compromise between optical sensitivity and thin-layer electrochemical behavior. The spectroelectrochemical traits of the cell in both batch and flow modes were evaluated using aqueous ferricyanide and compare favorably to those reported previously for similar cells.
منابع مشابه
Miniaturized optical chemosensor for flow-based assays
A cost-effective, highly compact, and versatile optoelectronic device constructed of two ordinary light emitting diodes compatible with optosensing films has been developed. This fibreless device containing chemoreceptor, semiconductor light source, and detector integrated in a miniaturized flow-through cell of low microliter internal volume works as a complete photometric chemical sensor suita...
متن کاملEasily Constructed Microscale Spectroelectrochemical Cell.
The design and performance of an easily constructed cell for microscale spectroelectrochemical analysis is described. A cation exchange polymer film, Nafion, was used as a salt bridge to provide ionic contact between a small sample well containing a coiled wire working electrode and separate, larger wells housing reference and auxiliary electrodes. The cell was evaluated using aqueous ferri/fer...
متن کاملAmperometric lysine bioprobes analysis in feeds.
Amperometric enzyme electrode probes have been constructed for the specific determination of L-lysine and used in batch and flow analysis. The enzyme lysine oxidase was immobilized on a preactivated polymer support which was placed on a platinum electrode. Additional blocking membranes conferred high stability, reproducibility and avoided electrochemical and enzyme interferences. Parameters inc...
متن کاملSimultaneous determination of lithium, sodium and potassium in blood serum by flame photometric flow-injection analysis.
A simultaneous flow-injection analysis (FIA) manifold that could analyse three ions from a single injection was designed, constructed, calibrated and used successfully to analyse Li(+), Na(+) and K(+). This FIA method was 10 times faster than the batch technique. The sample volume required was a fraction of about 1/110 to 1/75 that of the batch technique. The outputs were quite reproducible and...
متن کاملThe effect of vertical injection of reactants to the membrane electrode assembly on the performance of a PEM fuel cell
In order to present a new and high performance structure of PEM fuel cell and study the influence of the flow direction and distribution on the rate of reactants diffusion, three novel models of vertical reactant flow injection into the anode and cathode reaction area field have been introduced. They consist of one inlet and two inlets and also a continuous channel. The governing equations on t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 74 3 شماره
صفحات -
تاریخ انتشار 2002