Exercise Physiology Comparative Effectiveness of Exercise Electrocardiography With or Without Myocardial Perfusion Single Photon Emission Computed Tomography in Women With Suspected Coronary Artery Disease Results From the What Is the Optimal Method for Ischemia Evaluation in Women (WOMEN) Trial
نویسنده
چکیده
Background—There is a paucity of randomized trials regarding diagnostic testing in women with suspected coronary artery disease (CAD). It remains unclear whether the addition of myocardial perfusion imaging (MPI) to the standard ECG exercise treadmill test (ETT) provides incremental information to improve clinical decision making in women with suspected CAD. Methods and Results—We randomized symptomatic women with suspected CAD, an interpretable ECG, and 5 metabolic equivalents on the Duke Activity Status Index to 1 of 2 diagnostic strategies: ETT or exercise MPI. The primary end point was 2-year incidence of major adverse cardiac events, defined as CAD death or hospitalization for an acute coronary syndrome or heart failure. A total of 824 women were randomized to ETT or exercise MPI. For women randomized to ETT, ECG results were normal in 64%, indeterminate in 16%, and abnormal in 20%. By comparison, the exercise MPI results were normal in 91%, mildly abnormal in 3%, and moderate to severely abnormal in 6%. At 2 years, there was no difference in major adverse cardiac events (98.0% for ETT and 97.7% for MPI; P 0.59). Compared with ETT, index testing costs were higher for exercise MPI (P 0.001), whereas downstream procedural costs were slightly lower (P 0.0008). Overall, the cumulative diagnostic cost savings was 48% for ETT compared with exercise MPI (P 0.001). Conclusions—In low-risk, exercising women, a diagnostic strategy that uses ETT versus exercise MPI yields similar 2-year posttest outcomes while providing significant diagnostic cost savings. The ETT with selective follow-up testing should be considered as the initial diagnostic strategy in symptomatic women with suspected CAD. Clinical Trial Registration—http://www.clinicaltrials.gov. Unique identifier: NCT00282711. (Circulation. 2011;124:1239-1249.)
منابع مشابه
Coronary Artery Disease: Results From the What Is the Optimal Method for Ischemia Perfusion Single Photon Emission Computed Tomography in Women With Suspected Comparative Effectiveness of Exercise Electrocardiography With or Without Myocardial
Veledar, Rory Hachamovitch, James A. Arrighi, C. Noel Bairey Merz, Raymond J. Gibbons, Leslee J. Shaw, Jennifer H. Mieres, Robert H. Hendel, William E. Boden, Martha Gulati, Emir Evaluation in Women (WOMEN) Trial Coronary Artery Disease: Results From the What Is the Optimal Method for Ischemia Perfusion Single Photon Emission Computed Tomography in Women With Suspected Comparative Effectiveness...
متن کاملComparative effectiveness of exercise electrocardiography with or without myocardial perfusion single photon emission computed tomography in women with suspected coronary artery disease: results from the What Is the Optimal Method for Ischemia Evaluation in Women (WOMEN) trial.
BACKGROUND There is a paucity of randomized trials regarding diagnostic testing in women with suspected coronary artery disease (CAD). It remains unclear whether the addition of myocardial perfusion imaging (MPI) to the standard ECG exercise treadmill test (ETT) provides incremental information to improve clinical decision making in women with suspected CAD. METHODS AND RESULTS We randomized ...
متن کاملMyocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]
Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...
متن کاملImpact of hypertension on the accuracy of exercise stress myocardial perfusion imaging for the diagnosis of coronary artery disease.
AIM To compare the accuracy of exercise stress myocardial perfusion single photon emission computed tomography (SPECT) imaging for the diagnosis of coronary artery disease in patients with and without hypertension. METHODS A symptom limited bicycle exercise stress test in conjunction with 99m technetium sestamibi or tetrofosmin SPECT imaging was performed in 332 patients (mean (SD) age, 57 (1...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کامل