On Calibration of pH Meters

نویسندگان

  • K. L. Cheng
  • Da-Ming Zhu
چکیده

The calibration of pH meters including the pH glass electrode, ISE electrodes, buffers, and the general background for calibration are reviewed. Understanding of basic concepts of pH, pOH, and electrode mechanism is emphasized. New concepts of pH, pOH, as well as critical examination of activity, and activity coefficients are given. The emergence of new solid state pH electrodes and replacement of the salt bridge with a conducting wire have opened up a new horizon for pH measurements. A pH buffer solution with a conducting wire may be used as a stable reference electrode. The misleading unlimited linear Nernstian slope should be discarded. Calibration curves with 3 nonlinear portions for the entire 0—14 pH range due to the isoelectric point change effect are explained. The potential measurement with stirring or unstirring and effects by double layer (DL) and triple layer (TL) will be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On the Calibration of Reactive Energy Meters under Non Sinusoidal Conditions

− This paper is focused on the problems related to the calibration of the reactive energy meters on the place of installation of the electricity meter (on-site), using the load of the same electrical system. In the presence of harmonic distortion, the behaviour of the meters can go out of the limits imposed by the theoretical calibration curve, depending on the metric used by both reference sta...

متن کامل

On the methodologies for the calibration of static electricity meters in the presence of harmonic distortion

Abstrac t This paper is focused on the problems related to the calibration of static electricity meters with nonsinusoidal test waveforms. This is an up-to-date issue since the harmonic distortion levels are ever increasing, especially in low-voltage power systems, and in such conditions the performances of the modern static electricity meters can be negatively affected, depending on the implem...

متن کامل

Calibration Concept of Modern Power Meters

The power is the most important electromagnetic quantity from the metrological point of view, and for this reason the calibration techniques of high frequency power meters require a specific attention. Literature still refers to power meters of bolometer type, instruments that are mainly used almost only in the primary laboratories. Definitions, procedures, and calibration techniques elaborated...

متن کامل

Test Benches for Calibrating Custody Transfer Gas Meter

Several transmission and distribution companies in Western Europe operate test facilities for testing industrial meters like larger diaphragm gas meters, rotary gas meters and turbine gas meters. Alternatively, they lease mobile provers. Those installations are not suitable to perform the initial calibration (and try to save money on the calibration costs), but are suitable to perform all kind ...

متن کامل

Calibration of some Wright peak flow meters.

The performance of Wright peak flow meters is described using an absolute and precise calibration method. This showed errors as great as 25% with the peak flow meter and 40% with the mini peak flow meter. At large flow rates errors were less. The expected variation between individual peak flow meters was about 12%. The expected variation between individual mini peak flow meters was between 16% ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2005