Suction-assisted one-piece self-retaining wide-angle contact lens for vitrectomy.
نویسندگان
چکیده
INTRODUCTION We have developed a suction-assisted one-piece self-retaining wide-angle contact lens for vitrectomy. DESIGN The wide-angle contact lens is a one-piece lens without the case, making it lightweight. The contact inferior surface is enhanced by four quadrant plate extensions. A metal housing is attached to the side of the plate extension with an opening at the inferior surface. A negative suction device is attached to the housing of the lens. METHOD OF USE: A drop of viscoelastic is placed between the lens and the cornea. Suction created by a syringe device holds the contact lens on the cornea. CONCLUSION This specially designed lens is lightweight and eliminates the need for a skilled assistant to stabilize the contact lens. It provides a stable well-centered view of the peripheral fundus during vitreous surgery.
منابع مشابه
New self-retaining sutureless cellulose flanged disposable contact viewing system for vitreoretinal surgery.
The Super View HTC Hassan Tornambe Disposable Contact Lens (Insight Instruments, Stuart, FL) is a disposable flat contact lens with a cellulose flange and four cellulose footplates. The circular lens is manufactured from high-index optical grade thermoplastic material, with a lens diameter of 13 mm and edge thickness of 4.8 mm (Figure 1A). The anterior surface is flat, whereas the concave poste...
متن کاملCommercially available rigid gas-permeable contact lens for protecting the cornea from drying during vitrectomy with a wide viewing system
PURPOSE We evaluated the usefulness of commercially available materials for protecting the cornea from drying during vitrectomy with a wide-angle viewing system. METHODS THREE VITREORETINAL SURGEONS EVALUATED FUNDUS VISIBILITY DURING VITRECTOMY ON THE IMAGES OF FIVE STUDY MATERIALS USED ON THE CORNEA: balanced saline solution, a viscoelastic agent, a vitrectomy contact lens, a rigid gas perme...
متن کاملCombined use of high-reflective index vitrectomy meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery
BACKGROUND The aim of this study was to assess the combined use of a high-reflective index vitrectomy (HHV) meniscus contact lens and a noncontact wide-angle viewing system in vitreous surgery. METHODS Twenty-three gauge vitrectomy was performed with combined use of a HHV meniscus contact lens and a noncontact wide-angle viewing system. When delicate manipulation of the retina such as interna...
متن کاملA new lens for observing fundus with a noncontact wide-angle viewing system
Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems when using a noncontact-type wide-angle viewing system. This study used a newly commercialized lens for observing the fundus with a noncontact wide-angle viewing system. The lens used has a very thin meniscus made of polymethyl methacrylate and a large outer diameter. Following t...
متن کاملVideoendoscope-guided fluorescein-assisted vitrectomy for phakic malignant glaucoma.
Malignant glaucoma is a rare secondary glaucoma classically occurring after intraocular surgery in eyes with primary angle closure. Pars plana vitrectomy is reserved for the treatment of malignant glaucoma when medical and laser treatment fail. The primary aim of surgery is the removal of the anterior vitreous to reduce resistance to aqueous flow into the anterior chamber. In phakic eyes, conve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic research
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2003