Determination of iopromide in environmental waters by ion chromatography - ICP - MS

نویسندگان

  • Armando Durazo
  • Tarun Anumol
  • Shane A. Snyder
چکیده

The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127). Determination of iopromide in environmental waters by ion chromatography-ICP-MS

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect determination of trace amounts of fluoride in natural waters by ion chromatography: a comparison of on-line post-column fluorimetry and ICP-MS detectors.

An alternative method for the determination of trace levels of fluoride in drinking and sea-water samples is presented. It is based on the formation of the aluminium monofluoride complex in excess of Al3+ and separation of the two species formed (AlF2+ and Al3+) in a small (5 cm long, CG2) ion exchange guard column. The final determination is accomplished by both ICP-MS specific detection and p...

متن کامل

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method....

متن کامل

Evaluation of Hydrodynamic Chromatography Coupled with UV-Visible, Fluorescence and Inductively Coupled Plasma Mass Spectrometry Detectors for Sizing and Quantifying Colloids in Environmental Media

In this study, we evaluated hydrodynamic chromatography (HDC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of nanoparticles in environmental samples. Using two commercially available columns (Polymer Labs-PDSA type 1 and 2), a set of well characterised calibrants and a new external time marking method, we showed that flow rate and eluent composition have f...

متن کامل

Inorganic trace analysis by mass spectrometry

Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ionimplanted semiconductors...

متن کامل

Determination of Actinide Elements in Environmental Samples by Icp-ms

DETERMINATION OF ACTINDE ELEMENTS iN ENVIRONMENTAL SAMPLES BY ICP-MS Jason Bedford Truscott Methods for the determination of the actinide elements m water, biological, soil and sediment samples have been developed usmg on-line sohd phase extraction and high performance liquid chromatography (I{PLC) coupled with mductively coupled plasma mass spectrometry (ICP-MS) Initial applications utilised a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012