Quantitative micro-computed tomography: a non-invasive method to assess equivalent bone mineral density.
نویسندگان
چکیده
One of the many applications of micro computed tomography (microCT) is to accurately visualize and quantify cancellous bone microstructure. However, microCT based assessment of bone mineral density has yet to be thoroughly investigated. Specifically, the effects of varying imaging parameters, such as tube voltage (kVp), current (microA), integration time (ms), object to X-ray source distance (mm), projection number, detector array size and imaging media (surrounding the specimen), on the relationship between equivalent tissue density (rhoEQ) and its linear attenuation coefficient (micro) have received little attention. In this study, in house manufactured, hydrogen dipotassium phosphate liquid calibration phantoms (K2HPO4) were employed in addition to a resin embedded hydroxyapatite solid calibration phantoms supplied by Scanco Medical AG Company. Variations in current, integration time and projection number had no effect on the conversion relationship between micro and rhoEQ for the K2HPO4 and Scanco calibration phantoms [p>0.05 for all cases]. However, as expected, variations in scanning tube voltage, object to X-ray source distance, detector array size and imaging media (referring to the solution that surrounds the specimen in the imaging vial) significantly affected the conversion relationship between mu and rhoEQ for K2HPO4 and Scanco calibration phantoms [p<0.05 for all cases]. A multivariate linear regression approach was used to estimate rhoEQ based on attenuation coefficient, tube voltage, object to X-ray source distance, detector array size and imaging media for K2HPO4 liquid calibration phantoms, explaining 90% of the variation in rhoEQ. Furthermore, equivalent density values of bovine cortical bone (converted from attenuation coefficient to equivalent density using the K2HPO4 liquid calibration phantoms) samples highly correlated [R2=0.92] with the ash densities of the samples. In conclusion, Scanco calibration phantoms can be used to assess equivalent bone mineral density; however, they cannot be scanned with a specimen or submerged in a different imaging media. The K2HPO4 liquid calibration phantoms provide a cost effective, easy to prepare and convenient means to perform quantitative microCT analysis using any microCT system, with the ability to choose different imaging media according to study needs. However, as with any liquid calibration phantom, they are susceptible to degradation over time.
منابع مشابه
Comparison of quantitative computed tomography-based measures in predicting vertebral compressive strength.
Patient-specific measures derived from quantitative computed tomography (QCT) scans are currently being developed as a clinical tool for vertebral strength prediction. QCT-based measurement techniques vary greatly in structural complexity and generally fall into one of three categories: (1) bone mineral density (BMD), (2) "mechanics of solids" (MOS) models, such as minimum axial rigidity (the p...
متن کاملAssessment of bone fragility with clinical imaging modalities.
INTRODUCTION Osteoporotic fractures are a vital public health concern and have created a great economic burden to our society. Therefore, early diagnosis of patients with high risk of osteoporotic fractures is essential. The current gold standard for assessment of fracture risk is the measurement of bone mineral density using dual-energy X-ray absorptiometry. However, such techniques are not ve...
متن کاملNon-invasive assessment of failure torque in rat bones with simulated lytic lesions using computed tomography based structural rigidity analysis.
This study applies CT-based structural rigidity analysis (CTRA) to assess failure torque of rat femurs with simulated lytic defects at different locations (proximal and distal femur) and diameters (25% and 50% of the cross-section at the site), and compared the results to those obtained from mechanical testing. Moreover, it aims to compare the correlation coefficients between CTRA-based failure...
متن کاملBone Mineral Density Changes in Growing and Training Thoroughbreds
Bone mineral density contributes to bone strength, and can be measured accurately in the distal limb of growing or training young horses. In training horses, changes occur within less than 3 months, and consist of trabecular thickening in the subchondral area and specific areas of the body of the epiphysis of longbones and the cuboidal bones. In the growing horse, variation in mineral density b...
متن کاملA Physician’s Guide to QCT BMD Testing
Quantitative Computed Tomography or “QCT” is a fast, non-invasive bone mineral density (BMD) exam of the lumbar spine or proximal femur, which utilizes low dose scan protocols on a standard Computed Tomography (CT) scanner. Originally developed in the early 80’s, QCT has several advantages over Dual-energy X-ray Absorptiometry (DXA) for the measurement of BMD in patients with degenerative disea...