A Comparative Evaluation of Smear Layer Removal Using Apical Negative Pressure (EndoVac), Sonic Irrigation (EndoActivator) and Er:YAG laser -An In vitro SEM Study

نویسندگان

  • Sanghamitra Suman
  • Promila Verma
  • Aseem Prakash-Tikku
  • Rhythm Bains
  • Vijay Kumar-Shakya
چکیده

BACKGROUND This study aimed to compare the smear layer removing efficacy of the EndoActivator, EndoVac and Er:YAG laser in extracted mandibular premolars, at the apical, middle and coronal third of root canal, through scanning electron microscopy. MATERIAL AND METHODS 40 extracted mandibular premolars were decoronated to a standardized length of 12 mm. Specimens were shaped to ProTaper F4 size and irrigated with 5.25% sodium hypochlorite at 370C between instrumentation. Teeth were divided into four groups (n=10), one control (needle irrigation) and three experimental, according to the irrigant activation technique used i.e. sonic irrigation (EndoActivator), apical negative pressure (EndoVac) or laser (Er:YAG). The final irrigants used were 10ml,17% ethylenediaminetetraacetic acid (EDTA) and 10ml, 5.25% sodium hypochlorite. Root canals were then split longitudinally and observed under a scanning electron microscope. The presence of smear layer at the apical, middle and coronal third of root canal was evaluated. Scores were analyzed by Kruskal-Wallis and Mann-Whitney U tests. Intraexaminer and interexaminer reliability were determined by Kappa test. RESULTS The EndoVac system was significantly more effective in removing debris from the apical third than all other groups. EndoActivator performed better than laser at the apical third. All three experimental groups (EndoVac, EndoActivator, and laser) were better than needle irrigation at the middle and apical third. At the coronal third, no significant difference was seen between the four groups. CONCLUSIONS None of the activation systems completely removes the smear layer from the dentine walls; nevertheless, EndoVac is significantly better in removing debris from the apical third of canal. Key words:EndoVac, EndoActivator, Er:YAG laser, smear layer, scanning electron microscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smear layer removal and canal cleanliness using different irrigation systems (EndoActivator, EndoVac, and passive ultrasonic irrigation): field emission scanning electron microscopic evaluation in an in vitro study.

INTRODUCTION The purpose of this study was to evaluate the effectiveness of different irrigating methods in removing the smear layer at 1, 3, 5, and 8 mm from the apex of endodontic canals. METHODS Sixty-five extracted single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Specimens were shaped to ProTaper F4 (Dentsply Maillefer, Ballaigues, Switzerland) ...

متن کامل

Efficiency of Different Endodontic Irrigation and Activation Systems in Removal of the Smear Layer: A Scanning Electron Microscopy Study

Introduction This in vitro study was designed to evaluate and compare different endodontic irrigation and activation systems for removal of the intracanal smear layer. Methods and Materials Forty recently extracted, non-carious human intact single rooted premolars were selected and divided into five groups (n=10) according to the root canal irrigation systems; syringe and needle irrigation (C...

متن کامل

Comparison of the cleaning efficacy of conventional syringe irrigation, Endovac and Laser in removing smear layer from the root canal wall using scanning electron microscope: An in vitro study

Introduction-Debridement is the aim of and also a big challenge to endodontic treatment especially in the apical portion of the root canal. Because of the complexity of the root canal anatomy and the limitations of instrumentation, irrigation has gained increasing attention and one improvement in this respect is irrigant activation. The aim of this study is to Compare the cleaning efficacy of c...

متن کامل

Effectiveness of different irrigation systems on smear layer removal: A scanning electron microscopic study

OBJECTIVES To evaluate effectiveness of the apical negative pressure irrigation (EndoVac), passive ultrasonic irrigation (PUI), and conventional needle irrigation (CI) systems on smear layer (SR) removal. MATERIALS AND METHODS Sixty single-rooted canines were prepared using NiTi rotary files and subjected to different irrigation regimens: EndoVac with NaOCl (Group 1) or NaOCl/EDTA (Group 2); ...

متن کامل

Effectiveness of the EndoActivator System in removing the smear layer after root canal instrumentation.

INTRODUCTION Elimination of the smear layer after root canal instrumentation requires the use of irrigating solutions. This cleaning can be completed with passive ultrasonic or sonic irrigation. The aim of this study was to evaluate the effectiveness of the EndoActivator System in removing the smear layer after rotary root canal instrumentation, with and without a final flush of 17% ethylenedia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017