Real –time Monitoring of Overhead Transmission Line and Its Risk Assessment
نویسندگان
چکیده
To avoid unnecessary accident and to insure that overhead transmission lines operate safely, on-line monitoring operation state and dynamic security evaluation are necessary. Dynamic Line Rating (DLR) system has been introduced in monitoring the real-time weather and line conditions. The conductor temperature in operation is affected by complex components. This paper analyzed the characteristics of operating line temperature, and found that the line load, tension and wind speed are the main contributors to conductor temperature. The conductor temperature model affected by multiple factors based on multiple regression analyses is set up right after parameter estimations. The experiments did on 110kV lines have been discussed and proved the accuracy of the temperature model. In addition, to maintain transmission line reliability under uncertainty, on-line risk assessment is provided to evaluate thermal overload risk of overhead transmission lines. The main results of experimental studies in field are also presented.
منابع مشابه
Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملEfficient Simulation of Temperature Evolution of Overhead Transmission Lines Based on Analytical Solution and NWP
1 Abstract --Transmission lines are vital components in power systems. Outages of transmission lines caused by over-temperature is a major threat to system reliability, so it is necessary to efficiently simulate line temperature under both normal operation conditions and foreseen fault conditions. Existing methods based on thermalsteady-state analyses cannot support the simulation of transient ...
متن کاملHigh Frequency Analysis of Single Overhead Line Terminated to Grounded Arrester
In this paper, intelligent models based on fuzzy inference are proposed to analyze single overhead line terminated to arrester. This paper consists of two parts. The first one is modeling overhead line and the second one is related to modeling grounding system. In each part, the behavior of the problem is first represented as simple and unchanged membership functions. After then, effects of par...
متن کاملA Fiber Bragg Grating-Based Dynamic Tension Detection System for Overhead Transmission Line Galloping
Galloping of overhead transmission lines (OHTLs) may induce conductor breakage and tower collapse, and there is no effective method for long distance distribution on-line galloping monitoring. To overcome the drawbacks of the conventional galloping monitoring systems, such as sensitivity to electromagnetic interference, the need for onsite power, and short lifetimes, a novel optical remote pass...
متن کاملPotentiometric Method to Determine Montelukast Sodium in its Tablets with In-line Monitoring of its Dissolution Behaviour
Direct drug determination without any pervious treatment steps is the most environmentally friendly method of analysis. Traditional analysis methods usually involve a pre-treatment step before analysis and this consumes time and organic solvents. This work describes direct potentiometric method by using ion selective electrode to determine Montelukast Sodium in its pure drug substance and in ta...