Interaction of high intensity focused ultrasound with biological materials
نویسندگان
چکیده
This work is motivated by possible medical applications of focused ultrasound in minimally invasive treatment of a variety of disorders. The mechanical and thermal effects caused by high-frequency ultrasound in different material systems are calculated using a finite element based program called PZflex. The pressure distributions generated by plane as well as focused ultrasound beams are presented. For the focused beam, the temperature distribution in the focal zone is also calculated. The results indicate that the heating efficiency of the ultrasound energy in the focal region depends on the exciting frequency and the geometry of the focal zone depends on the material being tested. At higher excitation energies, cavitation and nonlinear effects need to be included in the simulations. These effects are under current investigation.
منابع مشابه
Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کامل1-3 Piezoelectric Composites for High Power Ultrasonic Transducer Applications
In this paper, we demonstrated that 1-3 PZT/polymer composites, fabricated using PZT-4 ceramic and a polymer possessing a high glass transition temperature and low loss, can be used as high power ultrasonic transducer materials for high intensity focused ultrasound (HIFU) applications. The mechanical quality factor of the 1-3 composite with 64% ceramic volume fraction is over 200. The dielectri...
متن کاملComparative study of temperature measurements in ex vivo swine muscle and a tissue-mimicking material during high intensity focused ultrasound exposures.
Tissue-mimicking materials (TMMs) can provide a convenient, stable, and reproducible means for testing high intensity focused ultrasound (HIFU) devices. When TMMs containing thermal sensors are used to measure ultrasound-induced temperature rise, it is important that measurement results reasonably represent those that occur in biological tissue. Therefore the aim of this paper is to compare the...
متن کاملNonlinear absorption in biological tissue for high intensity focused ultrasound.
In recent years the propagation of the high intensity focused ultrasound (HIFU) in biological tissue is an interesting area due to its potential applications in non-invasive treatment of disease. The base principle of these applications is the heat effect generated by ultrasound absorption. In order to control therapeutic efficiency, it is important to evaluate the heat generation in biological...
متن کامل