Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial.
نویسندگان
چکیده
PURPOSE The purposes of this study were to: (1) determine patient satisfaction with implant-supported mandibular overdentures using magnet, bar-clip, and ball-socket attachments; and (2) assess the relation between maximum bite force and patient satisfaction. MATERIALS AND METHODS In a cross-over clinical trial, 18 edentulous patients with mandibular denture complaints received two mandibular implants and new mandibular and maxillary dentures. The mandibular denture was initially without any kind of attachment system, but it was fitted with one of the attachment types after 3 months. The attachments were changed 3 months thereafter, in random order. A questionnaire on denture complaints was administered at baseline (with the old denture), after 3 months of function with the new denture without attachments, and after 3 months of function with each of the attachments (within-subject comparison). In addition, patients were asked to express their overall appreciation of their dentures on a VAS. Patients' preferences were determined at the end of the experiment. Maximum bite forces were obtained from a previous study with the same population. Five scales of denture complaints were constructed. Mean scale and VAS scores at the five evaluation points were compared among the groups. Pearson correlation was calculated between maximum bite force and scale and VAS scores. RESULTS AND CONCLUSION Mandibular implant-supported overdenture treatment reduced various denture complaints. The VAS score better reflected patients' preferences than did scale score. Patients strongly preferred bar-clip (10/18 subjects) and ball-socket attachments (7/18 subjects) over magnet attachments (1/18 subjects). Patients' preferences could not be predicted on the basis of baseline observations. Maximum bite force was not correlated to scale or VAS score. Hence, patients with higher maximum bite forces were not necessarily more satisfied.
منابع مشابه
Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments.
PURPOSE The aim of this study was to evaluate patient satisfaction and clinical and prosthetic outcomes of two-implant mandibular overdenture treatment with different attachment types after 10 years of function. MATERIALS AND METHODS In a crossover clinical trial, 18 edentulous subjects with complaints regarding their mandibular dentures received two implants and a new denture with magnet, ba...
متن کاملAttachment systems for mandibular implant overdentures: a systematic review
PURPOSE The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exc...
متن کاملTwo Years Retrospective Evaluation of Overdenture Retained by Symphyseal Single Implant Using Two Types of Attachments
BACKGROUND This study was aimed to evaluate complete mandibular overdentures retained by a symphyseal single implant using ball and magnet attachments in both clinical and radiographic evaluation. MATERIALS AND METHODS Ten dental press fit titanium implants were installed in the lower jaws of completely edentulous patients according to two-stage surgical protocol. For each patient, one implan...
متن کاملMagnet-retained implant-supported overdentures: review and 1-year clinical report.
Open-field aluminum-nickle-cobalt magnets have been used in prosthodontics for many years, but success has been limited because these magnets are susceptible to corrosion by the saliva and because their retentive force is weak relative to the initial retention offered by mechanical attachments. More recently, magnets have been made from alloys of the rare earth elements samarium and neodymium, ...
متن کاملComparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of prosthodontics
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2005