The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia.

نویسندگان

  • Elizabeth E Foglia
  • Robin K Whyte
  • Aasma Chaudhary
  • Antonio Mott
  • Jodi Chen
  • Kathleen J Propert
  • Barbara Schmidt
چکیده

To compare pulse oximetry measurement bias between infants with hypoxemia with either dark skin or light skin with Masimo Radical 7 and Nellcor Oximax. There was no significant difference in systematic bias based on skin pigment for either oximeter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can we Replace Arterial Blood Gas Analysis by Pulse Oximetry in Neonates with Respiratory Distress Syndrome, who are Treated According to INSURE Protocol?

Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

متن کامل

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

Pulse oximetry in pediatric practice.

The introduction of pulse oximetry in clinical practice has allowed for simple, noninvasive, and reasonably accurate estimation of arterial oxygen saturation. Pulse oximetry is routinely used in the emergency department, the pediatric ward, and in pediatric intensive and perioperative care. However, clinically relevant principles and inherent limitations of the method are not always well unders...

متن کامل

بررسی سطح دانش کارکنان پزشکی و پیراپزشکی در باره پالس اکسیمتری در بخشهای اتاق عمل و مراقبتهای ویژه بیمارستانهای دانشگاه علوم پزشکی دانشگاه تهران 

Background and aim: One of the most important technological advancements for monitoring patients -- especially in anesthesia, recovery, and Intensive Care stages -- is pulse oximetry which can measure the oxygen saturation of arterial blood (spo2) and show hypoxemia before it is clinically observable. Therefore, it is necessary for the individuals who are responsible for treating and taking car...

متن کامل

فاکتورهای پیش بینی کننده کاهش اشباع اکسیژن خون شریانی در طی آندوسکوپی فوقانی در بیماران بدون دریافت داروی آرامبخش

Introduction: Hypoxemia can occur during upper gastrointestinal endoscopy with or without pharmacological sedation. Pulse oximetry saturation (SpO2) levels were assessed in patients attending for routine unsedated diagnostic upper gastrointestinal endoscopy to identify factors associated with oxygen desaturation. Methods: A total of 300 patients who underwent upper gastrointestinal endoscopy w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of pediatrics

دوره 182  شماره 

صفحات  -

تاریخ انتشار 2017