Beam Trajectory Control of the Future Compact Linear Collider
نویسندگان
چکیده
The future Compact LInear Collider (CLIC) currently under design at CERN (European Organization for Nuclear Research) would create high-energy particle collisions between electrons and positrons, and provide a tool for scientists to address many of the most compelling questions about the fundamental nature of matter, energy, space and time. In accelerating structure, it is well-established that vibrations generated by the ground motion constitute the main limiting factors for reaching the luminosity of 10 cms. Several methods have been proposed to counteract this phenomena and active vibration controls based on the integration of mechatronic systems into the machine structure is probably one of the most promising. This paper studies the strategy of the vibration suppression. Active vibration control methods, such as optimized parameter of a numerical compensator, adaptive algorithm with real time control are investigated and implemented in the simulation layout. The requirement couldn’t be achieved without the study of activepassive isolation able to damp high frequency ground motion. Thus, a pattern of a potential active/passive isolation has been proposed opening up prospects on the design of a future mechanical isolation.
منابع مشابه
A Dispersion - Free Trajectory Correction Technique for Linear
In this paper, we describe a new trajectory correction technique for high energy linear accelerators. Current correction techniques force the beam trajectory to follow misalignments of the Beam Position Monitors (BPMs). Since the particle bunch has a finite energy spread and particles with different energies are deflected differently, this causes " chromatic " dilution of the transverse beam em...
متن کاملA New Trajectory Correction Technique for Linacs’
In this paper, we describe a new trajectory correction technique for high energy linear accelerators. Current correction techniques force the beam trajectory to follow misalignments of the Beam Position Monitors (BPMs). Since the particle bunch has a finite energy spread and particles with different energies are deflected differently, this causes “chromatic” dilution of the transveise beam emit...
متن کاملSimulation of an Intra-pulse Interaction Point Feedback for Future Linear Colliders
In future normal-conducting linear colliders, the beams will be delivered in short bursts with a length of the order of 100 ns. The pulses will be separated by several ms. In order to maintain high luminosity, feedback is necessary on a pulse-to-pulse basis. In addition, intra-pulse feedback that can correct beam positions and angles within one pulse seem technically feasible. The likely perfor...
متن کاملBeam Dynamics of the Interaction Region Solenoid in a Linear Collider Due to a Crossing Angle∗
Future linear colliders may require a nonzero crossing angle between the two beams at the interaction point. This requirement in turn implies that the beams will pass through the strong interaction region (IR) solenoid with an angle, and thus that the component of the solenoidal field perpendicular to the beam trajectory is nonzero. The interaction of the beam and the solenoidal field in the pr...
متن کاملStabilization study at the sub-nanometer level at the interaction point of the future Compact Linear Collider
The Compact LInear Collider (CLIC) is currently under design at CERN (European Organization for Nuclear Research). It would create high-energy particle collisions between electrons and positrons, and provide a tool for scientists to address many of the most compelling questions about the fundamental nature of matter, energy, space and time. In order to achieve the required luminosity of 10 cms,...
متن کامل