Surgical Management and Scheimpflug Analysis of an Atypical Lens Coloboma

نویسندگان

  • Julio C. Hernadez-Camarena
  • Eduardo Ayup-Arguijo
  • Eduardo Chavez-Mondragon
  • Arturo Ramirez-Miranda
چکیده

A lens coloboma is not a true coloboma; it is just a zonular absence that causes a defect in the lens equator and hence a more spherical lens. It can be isolated or in association with iris, choroid or retinal colobomas. Typically the defect is present at the site of the embryonic fissure, but it can be present elsewhere. This congenital defect can cause amblyopia, especially when it is associated with cataract. We describe a case of a 39-year-old male with an atypical coloboma that was managed successfully with phacoemulsification, capsular tension ring and intraocular lens implantation. Scheimpflug image analysis and full ophthalmological assessment were performed. Scheimpflug images demonstrated a notching of the lens equator and an absence of zonulae. During the surgical procedure an ophthalmic viscosurgical device was used to tamponade the vitreous, and after continuous curvilinear capsulorhexis the capsular tension ring was inserted to allow the surgeon to perform a safe phacoemulsification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract.

PURPOSE To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN Retrospective single-center study. METHODS In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam H...

متن کامل

Aniridia Associated with Lens Coloboma and Secondary Glaucoma Treated with Transcorneal Argon Laser Ciliary Body Photocoagulation: A Case Report

PURPOSE The aim of this study is to describe the management of cataract and refractory glaucoma in a case of congenital aniridia (AN)-1. METHODS In an 18-year-old female patient affected by congenital AN, bilateral coloboma of the zonula and lens, cataract and glaucoma, pars plana vitrectomy, cataract extraction and subsequent transcorneal ciliary body argon laser photocoagulation were perfor...

متن کامل

Intraocular lens implantation for patients with coloboma of the iris

The aim of this study was to analyze the techniques for intraocular lens (IOL) implantation in patients with coloboma of the iris. A retrospective cohort study was used to analyze the degree of iris coloboma and the characteristics of the crystalline lens in 56 patients with iris coloboma. The patients with a lesser degree of coloboma of the iris and an intact lens capsule were treated by iris ...

متن کامل

Repeatability and validity of lens densitometry measured with Scheimpflug imaging.

PURPOSE To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2012