Electrochemical investigation of Pb2+ binding and transport through a polymerized crystalline colloidal array hydrogel containing benzo-18-crown-6.

نویسندگان

  • Caroline D Geary
  • Imants Zudans
  • Alexander V Goponenko
  • Sanford A Asher
  • Stephen G Weber
چکیده

The transport of Pb2+ through a sensory gel, a polymerized crystalline colloidal array hydrogel with immobilized benzo-18-crown-6, is important for understanding and optimizing the sensor. Square wave voltammetry at a Hg/Au electrode reveals many parameters. The partition coefficient for Pb2+ into a control gel (no crown ether), K(p), is 1.00 +/- 0.018 (errors reported are SEM). The porosity, epsilon, of the gel is 0.90 +/- 0.01. Log K(c) for complexation in the gel is 2.75 +/- 0.014. Log K(c) in aqueous solution for Pb2+ with the ligand 4-acryloylamidobenzo-18-crown-6 is 3.01 +/- 0.010 with dissociation rate k(d) = (8.34 +/- 0.45) x 10(2) s(-1) and association rate k(f) = (8.79 +/- 0.025) x 10(7) M(-1) s(-1). The partition coefficient of the ligand 4-acryloylamidobenzo-18-crown-6 into the control gel, K(p,L) is 2.07 +/- 0.15. The diffusion coefficient of Pb2+ in the control gel is 6.72 x 10(-6) +/- 0.12 cm(2)/s. For the sensor gel, but not control gel, diffusion coefficients are location dependent. The range of diffusion coefficients for Pb2+ in the probed locations was found to be (6.11-12.60) x 10(-7) cm(2)/s for 0.91 mM Pb2+ and (2.84-9.39) x 10(-7) cm(2)/s for 0.35 mM Pb2+. Lead binding in the sensor gel is slightly less avid than in solution. This is attributed, in part, to the demonstrated affinity of the ligand 4-acryloylamidobenzo-18-crown-6 to the gel. Diffusion coefficients determined for the sensor gel were found to be location dependent. This is attributed to heterogeneities in the crown concentration in the gel. Analysis of diffusion coefficients and rate constants show that diffusion and not chemical relaxation will limit the time response of the material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of stimulated hydrogel volume changes in photonic crystal Pb2+ sensing materials.

We modeled the stimulated hydrogel volume transitions of a material which binds Pb2+ and is used as a photonic crystal chemical sensing material. This material consists of a polymerized crystalline colloidal array (PCCA) hydrogel which contains a crown ether molecular recognition group. The PCCA is a polyacrylamide hydrogel which embeds a crystalline colloidal array (CCA) of monodisperse polyst...

متن کامل

Cation identity dependence of crown ether photonic crystal Pb2+ sensing.

We quantitatively modeled the volume phase transition of a hydrogel containing a crystalline colloidal array with a crown ether ligand which binds Pb2+. The hydrogel volume response and the wavelength diffracted depend on the Pb2+ concentration and on both the ionic strength and the valence of the nonbinding ionic species. We successfully modeled the response of this hydrogel Pb2+ sensor to ion...

متن کامل

Epoxide functionalized polymerized crystalline colloidal arrays

We report the development of a novel method for functionalizing polymerized crystalline colloidal arrays (PCCA). This new method enables us to easily incorporate molecular recognition agents into the PCCA to produce chemical sensing materials that report on analyte concentration via diffraction of visible light. We copolymerize glycidyl methacrylate with acrylamide and N,N′-methylenebisacrylami...

متن کامل

Detection of Pb2+ using a hydrogel swelling microcantilever sensor.

Hydrogels containing benzo-18-crown-6 were used to modify microcantilevers for measurements of the concentration of Pb2+ in aqueous solutions. These microcantilevers undergo bending deflection upon exposure to solutions containing various Pb2+ concentrations as the result of a swelling of the hydrogels. It was found that a concentration of 10(-6) M Pb2+ can be detected using this technology. Ot...

متن کامل

Photonic crystal optrode sensor for detection of Pb2+ in high ionic strength environments.

We developed an optrode sensing device that utilizes a polymerized colloidal array (PCCA) photonic crystal material. This array diffracts light in the visible spectral region due to the periodic spacing of colloidal particles. The PCCA changes diffraction wavelength due to binding of Pb2+ to an 18-crown-6 ether molecular recognition agent. This optrode consists of a probe assembly that contains...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 77 1  شماره 

صفحات  -

تاریخ انتشار 2005