Experimental Results for Heat Gain and Radiant/Convective Split from Equipment in Buildings
نویسندگان
چکیده
Measurement of the heat loss from equipment in buildings is necessary in order to make accurate assessments of its impact on cooling loads. Recent advances in the design of buildings and improvement of the thermal characteristics of insulation materials and building envelope systems have significantly reduced the cooling load from external sources; however, the addition of various types of office, laboratory, and hospital equipment to buildings has become a major source of internal cooling load. Unfortunately, accurate information on the total heat gain from equipment is lacking in current handbooks. Some equipment includes a nameplate rating showing total power consumption, while other equipment does not have this. Some manufacturers measure maximum electric power consumption by the equipment and list that as power ratings on the nameplate or in the equipment literature, while some others list the maximum power capacity of the system. Since the manufacturers’ power ratings, if reported, are usually based on instantaneous measurement while equipment is working at maximum capacity, use of equipment nameplate values for cooling load calculations may lead to oversizing of air-conditioning equipment, resulting in extra initial cost as well as higher operating costs. On the other hand, underestimating the cooling load may result in insufficient cooling capacity. Another factor affecting calculation of cooling load is the split between the radiant and convective heat load from the equipment. The convection portion of the heat transferred from the equipment to the surroundings is an instantaneous load, since it is added to room air by natural or forced convection without time delay, whereas the radiation portion is absorbed by the surfaces of the room and then dissipated over time. AccuTHIS PREPRINT IS FOR DISCUSSION PURPOSES ONLY, FOR INCLUSION IN part without written permission of the American Society of Heating, Refrigerating Opinions, findings, conclusions, or recommendations expressed in this paper are t questions and comments regarding this paper should be received at ASHRAE no rate determination of cooling load is important in proper sizing of air-conditioning equipment. This article presents experimental results for the total heat gain and radiant/convective split from equipment in offices, hospitals, and laboratories. The nameplate vs. measured values, peak vs. average values, operational vs. idle values, and radiant vs. convective values are compared and discussed. Furthermore, a brief guideline for use of the experimental results by practicing engineers for estimating equipment cooling load is presented.
منابع مشابه
Heat Transfer Characteristics of Porous Radiant Burners Using Discrete-Ordinate Method (S2-Approximation)
This paper describes a theoretical study to investigate the heat transfer characteristics of porous radiant burners. A one dimensional model is used to solve the governing equations for porous medium and gas flow before the premixed flame to the exhaust gas. Combustion in the porous medium is modeled as a spatially dependent heat generation zone. The homogeneous porous media, in addition to its...
متن کاملHeat Transfer Study of Convective-Radiative Fin under the influence of Magnetic Field using Legendre Wavelet Collocation Method
The development and production of high performance equipment necessitate the use of passive cooling technology. In this paper, heat transfer study of convective-radiative straight fin with temperature-dependent thermal conductivity under the influence of magnetic field is carried out using Legendre wavelet collocation method. The numerical solution is used to investigate the effects of magnetic...
متن کاملInvestigation of convective heat transfer, pressure drop and efficiency of ZnO/water nanofluid in alternating elliptical axis tubes
In this study, for the first time, the heat transfer and the pressure drop of zinc oxide nanoparticles in alternating elliptical axis (AEA) tube have been investigated experimentally. The zinc oxide nanoparticles were at volumetric concentrations 1% and 2%. The base fluid was heat transfer oil and the experiments were conducted at constant wall temperature. Also, the study was done in Reynolds ...
متن کاملExperimental investigation of the physical mechanisms governing the spread of wildfires
11 One of the objectives of the present study is to gain a deeper understanding of the heat 12 transfer mechanisms that control the spread of wildfires. Five experimental fires were 13 conducted in the field across on plots of living vegetation. The lengths of the ignition lines 14 were set in the range of 20–30 m to reproduce wildfire front conditions as closely as possible. 15 The experiments...
متن کاملImproving the natural convective heat transfer of a rectangular heatsink using superhydrophobic walls: A numerical approach
The effect of utilizing superhydrophobic walls on improving the convective heat transfer in a rectangular heatsink has been studied numerically in this paper. The vertical walls were kept at isothermal hot-and-cold temperatures and horizontal walls were insulated. The boundary condition on the walls was: no-slip for regular, and slip (with slip length of 500 µm) for superhydrophobic walls. By c...
متن کامل