Simulation of Transformer With Aging Insulation and Incipient Faults

نویسندگان

  • X. Wang
  • Mark Sumner
  • Dave W. P. Thomas
چکیده

The development of the transformer insulation failure undergoes three stages: insulation aging, incipient faults and a short circuit. This paper presents a complete scheme to simulate single-phase transformers with insulation deterioration and arcing phenomena i.e. in the first two stages. The approach incorporates Transmission Line Methods (TLM), Jiles-Atherton Hysteretic Model, Composite Cassie-Mayr Arcing Model and Dielectric Model. A small 25kVA 11kV/220V power transformer with aging and incipient faults is taken as example for simulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of TLM and Cassie-Mayr Arc model on Transformer Aging and Incipient Faults Simulation

The development of the transformer insulation failure undergoes three stages: insulation aging, incipient faults and a short circuit. This paper presents a complete scheme to simulate single-phase transformers with insulation deterioration and arcing phenomena i.e. in the first two stages. The approach incorporates Transmission Line Methods (TLM), Jiles-Atherton Hysteretic Model, Composite Cass...

متن کامل

Transformer Internal Incipient Fault Simulations

Transformer fault detection and diagnosis is becoming more important due to the restructuring of the electric power industry. In this era of deregulation, loading transformers to their optimum capacity is becoming normal practice, which in turn applies high stresses on the insulation of the transformers and increases the probability of occurrence of internal incipient faults. Such faults can le...

متن کامل

Power Transformer Incipient Faults Monitoring

Power transformers are important and expensive components in the electric power system. The knowledge of the actual status of the transformer insulation behavior, load tap changer performance, temperature, and load condition is necessary in order to evaluate the service performance concerning reliability, availability and safety. Systems abnormalities, loading, switching and ambient condition n...

متن کامل

Performance Assessment of Anfis Applied to Fault Diagnosis of Power Transformer

Continuous monitoring of Power transformer is very much essential during its operation. Incipient faults inside the tank and winding insulation needs careful attention. Traditional ratio methods and Duval triangle can be employed to diagnose the incipient faults. Many times correct diagnosis due to the borderline problems and the existence of multiple faults may not be possible. Artificial inte...

متن کامل

Power Transformer Incipient Faults Diagnosis Based on Dissolved Gas Analysis

Incipient fault diagnosis of a power transformer is greatly influenced by the condition assessment of its insulation system oil and/or paper insulation. Dissolved gas-in-oil analysis (DGA) is one of the most powerfull techniques for the detection of incipient fault condition within oil-immersed transformers. The transformer data has been analyzed using key gases, Doernenburg, Roger, IEC and Duv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007