Improved detection of cerebral hypoperfusion with internal carotid balloon test occlusion and 99mTc-HMPAO cerebral perfusion SPECT imaging.

نویسندگان

  • S B Peterman
  • A Taylor
  • J C Hoffman
چکیده

A new method that employs a cerebral perfusion imaging agent, 99mTc-HMPAO, is described for identifying those patients who clinically pass an internal carotid artery balloon test occlusion but who then may develop a cerebral infarction after permanent occlusion. Test balloon occlusion of the internal carotid artery was performed in 17 patients, and 99mTc-HMPAO was injected intravenously while the balloon was inflated. The balloon was deflated and removed approximately 15-20 min later, and single-photon emission CT (SPECT) imaging of the brain was performed. In patients with an area of focal hypoperfusion, the 99mTc-HMPAO study was repeated the next day to determine if the hypoperfusion was due to the temporary balloon occlusion or to a preexisting abnormality. All 17 patients had normal neurologic examinations at the time of the balloon test occlusion. Fifteen had symmetric perfusion on the 99mTc-HMPAO SPECT scans. Five of these had permanent internal carotid artery occlusion, and four did not develop a neurologic deficit. One patient developed an ipsilateral watershed infarction after internal carotid artery occlusion during significant intraoperative hypotension. Two patients had ipsilateral regions of hypoperfusion with the test occlusion. Both these patients had repeat nonocclusion 99mTc-HMPAO SPECT studies that were normal. One patient is being followed. The second patient had ipsilateral EEG changes associated with temporary intraoperative occlusion of the internal carotid artery during aneurysm surgery. Although the numbers are relatively small, this study suggests that this protocol may be able to predict a good outcome after permanent carotid artery occlusion as well as to identify patients who are at greater risk for developing cerebral infarction after permanent occlusion.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing adequacy of collateral circulation during balloon test occlusion of the internal carotid artery with 99mTc-HMPAO SPECT.

A balloon test occlusion of the internal carotid artery was performed in 11 patients with internal carotid artery aneurysms. Tolerance by patients was assessed by a combination of clinical examination; angiography; electroencephalography; 99mTc-hexamethylpropyleneamine oxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with relative quantification; and, in four patients, 99m...

متن کامل

Increased cerebral perfusion after detachable balloon embolization of carotid cavernous fistula on technetium-99m-HMPAO brain SPECT.

Most symptoms and signs associated with a carotid cavernous fistula (CCF) are thought to be related to regurgitation of flow into cortical veins and to venous congestion. Arteriovenous shunting and secondary perfusion insufficiency is regarded as less important in causing symptoms. We describe a 27-yr-old male patient who had improvement of neurologic symptoms and signs after detachable balloon...

متن کامل

A comparative study of perfusion CT and 99mTc-HMPAO SPECT measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion

BACKGROUND AND PURPOSE Patients with internal carotid artery (ICA) occlusion can demonstrate impaired cerebral vascular reserve (CVR). The detection of CVR using single photon emission CT (SPECT) is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT) gained widely acceptance in stroke imaging. The p...

متن کامل

Comparison of technetium Tc 99m hexamethylpropyleneamine oxime single-photon emission tomograph with stump pressure during the balloon occlusion test of the internal carotid artery.

BACKGROUND AND PURPOSE Measuring blood pressure (stump pressure) in the distal internal carotid artery during occlusion of the internal carotid artery is reportedly a reliable safety index with which to predict ischemia following permanent occlusion of the internal carotid artery. We compared the stump pressure during occlusion of the internal carotid artery with single-photon emission CT (SPEC...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 1991