Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation.

نویسندگان

  • Abdel Nour Sibai
  • Elie Loutfi
  • Mohamad Itani
  • Anis Baraka
چکیده

BACKGROUND AND PURPOSE Literature review revealed major variations in the anatomic characteristics of the right internal jugular vein (IJV) and carotid artery (CA) by the use of the ultrasound machine. The purpose of this study is to examine the anatomical characteristics of the right IJV and CA and to evaluate the IJV cannulation outcomes by the standard ultrasound guided vs. ultrasound localized technique as suggested by Lin and colleagues. Additionally, the study assessed the impact of changing the ultrasound transducer direction on the location of right IJV relative to the CA METHODS: Patients (n = 100) were randomly assigned to either and ultrasound-guided or ultrasound-localized technique for IJV cannulation. The 'Site Rite' II ultrasound transducer was directed perpendicular to the floor at the apex of the clavicle-sternocleidomastoid triangle at the level of the cricoid cartilage with the head turned to contralateral side of cannulation and table tilted to 30 degrees in Trendelenburg position. Cannulation outcomes, including successful cannulation, access time, success time, and difficult cases were evaluated. Aborted difficult cases included prolonged procedural time exceeding four minutes and carotid puncture, and these were examined by technique, IJV size and its location relative to CA. The location of the IJV relative to CA was evaluated firstly with the ultrasound transducer directed perpendicular to the floor and secondly with the transducer directed perpendicular to the skin (Fig 1). RESULTS With the ultrasound transducer directed perpendicular to the floor, the depth of the IJV from the skin (15 mm) was comparable to its diameter (14.1 mm), while the CA A-P diameter was around half that of the IJV (7.4 mm) (Table 2). Also, the majority of patients showed lateral (51%) and posterolateral (14%) positions of the IJV relative to the CA. Directing the transducer perpendicular to the skin resulted in more anterolateral positions (77%) with 6% total overlap. Cannulation of the IJV was successful in 94% in both randomization groups, with 91.5% of the patients achieving first pass cannulation in the ultrasound-guided group and 87.2% in the ultrasound-localized (Table 3). Access time (6.9 +/- 13 sec and 5.9 +/- 14.6 sec) and success time (13.5 +/- 14.2 sec and 13.2 +/- 15.0 sec) were comparable for both groups. Reasons for aborted difficult cannulation included prolonged procedural time in 2% and carotid puncture in 4%, in both techniques. Compared to the successful cases, difficult cases were characterized by a significantly greater degree of anterolateral (exceeding 15 degrees) location ofthe IJV relative to the CA(p-value = 0.046) and a significantly smaller IJV size (mean 10.3 mm vs. 14.3 mm, p-value = 0.035) (Table 4). However, in multivariate analysis controlling for the technique utilized, only the relation between the size of IJV and the occurrence of difficult cases remained significant. With each 1 mm decrease in IJV size, there was a 37% significant increase in the risk of difficult cases. CONCLUSIONS Findings of the study show that both ultrasound guided and ultrasound localized techniques yield similar cannulation outcomes. Additional to the anteraloteral position of the IJV relative to the CA, a small IJV size constitutes a powerful predictor for the incidence of prolonged procedure time and carotid puncture for IJV canulation. Finally, the transducer direction has a significant impact on the assessment of the location of the IJV relative to the CA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-guided internal jugular venous cannulation in infants: a prospective comparison with the traditional palpation method.

BACKGROUND Percutaneous cannulation of the internal jugular vein in infants is technically more difficult and carries a higher risk of carotid artery puncture than in older children and adults. In this prospective study, the authors tested their hypothesis that using an ultrasound scanner would increase the success of internal jugular cannulation and decrease the incidence of carotid artery pun...

متن کامل

Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial.

AIM The aim of this study was to compare the short and long axis approaches to ultrasound guided right internal jugular vein cannulation with respect to indicators of success. METHODS Patients undergoing cardiac surgery requiring central venous cannulation (99 patients) were randomised to undergo either long or short axis ultrasound guided cannulation of the right internal jugular vein by a s...

متن کامل

A New Biplane Ultrasound Probe for Real-Time Visualization and Cannulation of the Internal Jugular Vein

Ultrasound guidance is recommended for cannulation of the internal jugular vein. Use of ultrasound allows you to identify relevant anatomy and possible anatomical anomalies. The most common approach is performed while visualizing the vein transversely and inserting the needle out of plane to the probe. With this approach needle tip visualization may be difficult. We report the use of a new bipl...

متن کامل

EF FECTS OF THE VALSALVA MANEUVER AND HEAD ROTATION ON INTERNAL JUGULAR VEIN DIAMETER AND LOCATION BY ULTRASONOGRAPHY

In order to determine the effect of Valsalva maneuver and head rotation on the internal jugular vein (IJV) diameter and cross-sectional area and overlap with the carotid artery (CA) and find the best technique for safe cannulation of the IJV and decrease the risk of CA puncture, the diameter of both the IJV and the CA and percentage of overlap between the two vessels and cross-sectional are...

متن کامل

Ultrasound-assisted cannulation of the internal jugular vein. A prospective comparison to the external landmark-guided technique.

BACKGROUND Central venous access is an essential part of patient management in many clinical settings and is usually achieved with a blinded, external landmark-guided technique. The purpose of this study is to evaluate whether an ultrasound technique can improve on the traditional method. METHODS AND RESULTS We prospectively evaluated an ultrasound-guided method in 302 patients undergoing int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Middle East journal of anaesthesiology

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2008