Intraocular pressure, corneal thickness, and corneal hysteresis in Steinert's myotonic dystrophy.
نویسندگان
چکیده
PURPOSE Low intraocular pressure (IOP) measured by Goldmann applanation tonometry (GAT) is one of the ocular manifestations of Steinert's myotonic dystrophy. The goal of this study was to evaluate the corneal-compensated IOP as well as corneal properties (central corneal thickness and corneal hysteresis) in patients with myotonic dystrophy. METHODS A total of 12 eyes of 6 patients with Steinert's myotonic dystrophy (dystrophy group) and 12 eyes of 6 age-, race-, and gender-matched healthy volunteers (control group) were included in the study. GAT, Dynamic Contour Tonometry (DCT-Pascal) and Ocular Response Analyzer (ORA) were used to assess the IOP. Central corneal thickness was obtained by ultrasound pachymetry, and corneal hysteresis was analyzed using the ORA device. In light of the multiplicity of tests performed, the significance level was set at 0.01 rather than 0.05. RESULTS The mean (standard deviation [SD]) GAT, DCT, and corneal-compensated ORA IOP in the dystrophy group were 5.4 (1.4) mmHg, 9.7 (1.5) mmHg, and 10.1 (2.6) mmHg, respectively. The mean (SD) GAT, DCT, and corneal-compensated ORA IOP in the control group was 12.6 (2.9) mmHg, 15.5 (2.7) mmHg, and 15.8 (3.4) mmHg, respectively. There were significant differences in IOP values between dystrophy and control groups obtained by GAT (mean, -7.2 mmHg; 99% confidence interval [CI], -10.5 to -3.9 mmHg; P<0.001), DCT (mean, -5.9 mmHg; 99% CI, -8.9 to -2.8 mmHg; P<0.001), and corneal-compensated ORA measurements (mean, -5.7 mmHg; 99% CI, -10.4 to -1.0 mmHg; P=0.003). The mean (SD) central corneal thickness was similar in the dystrophy (542 [31] µm) and control (537 [11] µm) groups (P=0.65). The mean (SD) corneal hysteresis in the dystrophy and control groups were 11.2 (1.5) mmHg and 9.7 (1.2) mmHg, respectively (P=0.04). CONCLUSIONS Patients with Steinert's myotonic dystrophy showed lower Goldmann and corneal-compensated IOP in comparison with healthy individuals. Since central corneal thickness and corneal hysteresis did not differ significantly between groups, the lower IOP readings documented in this dystrophy seem not to be related to changes in corneal properties.
منابع مشابه
Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملThe Heritability of Glaucoma-Related Traits Corneal Hysteresis, Central Corneal Thickness, Intraocular Pressure, and Choroidal Blood Flow Pulsatility
PURPOSE The purpose of this work was to investigate the heritability of potential glaucoma endophenotypes. We estimated for the first time the heritability of the pulsatility of choroidal blood flow. We also sought to confirm the heritability of corneal hysteresis, central corneal thickness, and 3 ways of measuring intraocular pressure. METHODS Measurements were performed on 96 first-degree r...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملCorneal hysteresis and its relevance to glaucoma
PURPOSE OF REVIEW Glaucoma is a leading cause of irreversible blindness worldwide. It is estimated that roughly 60.5 million people had glaucoma in 2010 and that this number is increasing. Many patients continue to lose vision despite apparent disease control according to traditional risk factors. The purpose of this review is to discuss the recent findings with regard to corneal hysteresis, a ...
متن کاملبررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 74 3 شماره
صفحات -
تاریخ انتشار 2011