Metabolite and diffusion changes in the rat brain after Leksell Gamma Knife irradiation.
نویسندگان
چکیده
Our study describes the time course of necrotic damage to the rat brain resulting from Leksell Gamma Knife (LGK) irradiation at a dose that was previously considered to be subnecrotic. A lesion induced in the rat hippocampus by 35 Gy irradiation was monitored by MRI, MRS, and DW-MRI for 16 months. T2-weighted images revealed a large hyperintense area with an increased apparent diffusion coefficient of water (ADCw), which occurred 8 months after irradiation, accompanied by metabolic changes (increase of lactate (Lac) and choline (Cho), and decrease of creatine (Cr) and N-acetyl aspartate (NAA), as determined by MRS) that indicated an edema. In two animals, the hyperintensity persisted and a postnecrotic cavity connected to enlarged lateral ventricles developed. In the rest of the animals, the hyperintensity started to decrease 9 months post-irradiation (PI), revealing hypointense areas with a decreased ADCw. Histology confirmed the MRI data, showing either scar formation or the development of a postnecrotic cavity.
منابع مشابه
Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملEvaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife
Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...
متن کاملLeksell gamma knife lesioning of the rat hippocampus: the relationship between radiation dose and functional and structural damage.
OBJECT The goals of the study were to determine at what dosage and after what interval impairment of hippocampal function occurs after Leksell gamma knife radiosurgery (GKS) of the rat hippocampus and to assess the associated structural changes. METHODS Long-Evans rats were irradiated with maximum doses of 25, 50, 75, 100, and 150 Gy, and four 4-mm isocenters were used to cover the hippocampu...
متن کاملDose distributions at extreme irradiation depths of gamma knife radiosurgery: EGS4 Monte Carlo calculations.
The accuracy of the dose planning system (Leksell GammaPlan), used in Gamma Knife (type B) radiosurgery at extreme irradiation depths, was verified using the Monte Carlo technique. EGS4 Monte Carlo calculations were employed to calculate the dose distribution along the x, y and z axes for an irradiation relatively shallow in a spherical bony cavity water phantom. Two different sizes of the coll...
متن کاملImage-guided Radiosurgery Using the Gamma Knife
Image guided brain surgery became a reality in the mid-1970s after the introduction of the fi rst methods to obtain axial imaging using computed tomography (CT) [9]. The recognition of cranial disease much earlier in its clinical course prompted the need for concomitant minimally invasive technologies to both diagnose and to treat the newly recognized brain tumors and vascular malformations. Su...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 52 2 شماره
صفحات -
تاریخ انتشار 2004