In-vitro investigation to evaluate the flexural bond strengths of three commercially available ultra low fusing ceramic systems to Grade II Titanium.
نویسندگان
چکیده
BACKGROUND This in-vitro investigation was designed to compare the flexural bond strengths of three commercially available ultra low fusing ceramic systems to Grade II Titanium and evaluate the type of bond failure through Scanning Electron Microscopy (SEM) and Energy Dispersion X ray Spectrum (EDS). MATERIALS & METHODS Sixty patterns of auto polymerizing resin of dimensions 25.1 mm X 3.1mm X 0.6mm each were fabricated from a stainless steel die. Titanium casting for all the samples was done in a Titanium casting machine. Ten samples were allotted to each of three groups randomly. Ceramic build up was done step by step using the manufacturers' instructions. Flexural Bond strength tests for the samples were performed by using a 3-point bending test on a Universal testing machine in compliance with Deutsches Institut für Normung (DIN) 13.927 draft. After the tests were completed, three samples, one from each group were selected randomly for the subsequent Scanning Electronic Microscopy (SEM) studies to characterize the type and morphology of the fracture in representative specimens. RESULTS The maximum load to fracture the porcelain was recorded for each specimen. All the means of the three groups were compared by one-way Analysis of Variance (ANOVA) and it was found that Group I & Group III had significantly higher bond strength values as compared with the Group II (P< 0.001). All the 10 samples of Group I & III gave bond strength values above the standard values of 25 MPa. There was statistically significant difference in the bond strengths between Group I & Group III (t = 2.76 and P< 0.05), between Group I & II (t = 5.09 and P< 0.001) and between Group II & Group III (t = 13.28 and P< 0.001). SEM studies revealed occurrence of cohesive type fractures in the ceramic body of samples belonging to Groups I & III, while there was adhesive failure at ceramo-metal junction of samples belonging to Group II. EDS Analysis supported the findings of SEM studies. CONCLUSION All the three ceramic systems fared better than the minimal recommended values stated by ISO 9693:1999 of 25MPa of which Orotig TiKrom was rated the best with values of 54.69 MPa. Vita TitanKeramik ranked second with values of 45.12MPa and the least values were obtained with Noritake Ti-22 with values of 27.76. The bond failure was predominantly cohesive in nature in case of Vita TitanKeramik and Orotig TiKrom; whereas adhesive failure was noticed in case of Noritake Ti-22. How to cite this article: Mabrurkar V, Habbu N, Hashmi SW, Musani S, Joshi N. In-vitro investigation to evaluate the flexural bond strengths of three commercially available ultra low fusing ceramic systems to Grade II Titanium. J Int Oral Health 2013;5(5):101-7.
منابع مشابه
Evaluation of low-fusing ceramic systems combined with titanium grades II and V by bending test and scanning electron microscopy.
The bond strength by three point bending strength of two metal substrates (commercially pure titanium or grade II, and Ti-6Al-4V alloy or grade V) combined to three distinct low-fusing ceramic systems (LFC) and the nature of porcelain-metal fracture by scanning electron microscopy (SEM) were evaluated. The results were compared to a combination of palladium-silver (Pd-Ag) alloy and conventional...
متن کاملمقایسه استحکام باند برشیIPS-Empress2 و سه نوع سمان رزینی Dual-Cure
Background and Aim: Cementation is one of the most critical steps of the porcelain restoration technique. However, limited information is available concerning the bond strength of current ceramic bonding systems. The aim of this study was to evaluate the shear bond strength of three dual-cure resin cements to IPS-Empress2 ceramics. Materials and Methods: In this experimental study, 30 pairs of ...
متن کاملEvaluation of Soldered Joints of Two Base Metal Ceramic Alloys: Supercast and Minalux
Background: Different soldering techniques have a variety of applications in dentistry. One of the most important uses of soldering is to join multiple-unit fixed partial dentures together. In this Study, two base metal alloys (Supercast and Minalux) were soldered and their tensile, compressive and flexural strengths were measured and compared to each other. Materials and methods: In this ...
متن کاملاثر زیرکونیا بر استحکام خمشی سرامیک IPS Empress 2
Background and Aim: All ceramic, inlay-retained resin bonded fixed partial denture is a conservative method for replacement of missing teeth, because of minimal tooth reduction. The connector between the retainer and the pontic is the weak point of these bridges. Reinforcement of ceramic core will increase the clinical longevity. The aim of this study was to determine the effect of zirconia on ...
متن کاملبررسی استحکام باند برشی کامپوزیت به فلزات غیرقیمتی با آمادهسازیهای سطحی مختلف1
Background and Aim: Replacing fractured ceramometal restorations may be the best treatment option, but it is costly. Many different bonding systems are currently available to repair the fractured ceramometal restorations. This study compared the shear bond strength of composite to a base metal alloy using 4 bonding systems.Materials and Methods: In this experimental in vitro study, fifty discs,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of international oral health : JIOH
دوره 5 5 شماره
صفحات -
تاریخ انتشار 2013