Dosimetrical Evaluation and Clinical Implementation of a Strut-adjusted-volume-implant Savi Device Used for Accelerated Partial Breast Irradiation

نویسندگان

  • Ş. MORCOVESCU
  • C. COSMA
  • J. D. MORTON
چکیده

The SAVI (the Strut Adjusted Volume Implant) device is one of the most novel devices used in Accelerated Partial Breast Irradiation (APBI). Various dosimetric parameters, as well as doses to adjacent critical structures, have been evaluated in 121 patients in this single institution 5-year retrospective study, using dose volume histogram (DVHs): Coverage Index (CI), cavity and planning target volumes (PTV and PTV_EVAL), Max Skin Dose (MSD), Max Chest Wall Dose (MCWD), Skin Bridges (SB), Chest-Wall Bridges (CWB). Our analysis demonstrates the dosimetric versatility and outlines the clinical implementation process of the SAVI brachytherapy device, especially for APBI cases that require more flexible dose optimization, for both coverage of PTV volumes and sparing of dose to adjacent critical structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy

Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...

متن کامل

Clinical implementation of a new HDR brachytherapy device for partial breast irradiation.

PURPOSE To present the clinical implementation of a new HDR device for partial breast irradiation, the Strut-Adjusted Volume Implant (SAVI), at the University of California, San Diego. METHODS AND MATERIALS The SAVI device has multiple peripheral struts that can be differentially loaded with the HDR source. Planning criteria used for evaluation of the treatment plans included the following do...

متن کامل

Comparison of planning techniques when air/fluid is present using the strut‐adjusted volume implant (SAVI) for HDR‐based accelerated partial breast irradiation

The presence of air/fluid surrounding implantable devices used for partial breast irradiation may significantly impact dose coverage to at-risk tissue. Of the 67 total patients retrospectively evaluated for this study, 32 (48%) had greater than 1 cc volume of air/fluid extending outside of the strut-adjusted volume implant (SAVI) device surface and were selected for comparison of planning appro...

متن کامل

Dosimetric performance of Strut-Adjusted Volume Implant: a new single-entry multicatheter breast brachytherapy applicator.

PURPOSE To evaluate the dosimetric performance and clinical utility of the Strut-Adjusted Volume Implant (SAVI) (Cianna Medical, Aliso Viejo, CA) applicator when used as the sole method of radiation therapy for patients with early breast carcinoma. METHODS AND MATERIALS The dosimetric performance of a Phase II clinical trial has been reported using the SAVI applicator for patients with early ...

متن کامل

Accelerated partial breast irradiation dosimetric criteria for the strut-adjusted volume implant.

PURPOSE Current guidelines for high-dose-rate accelerated partial breast irradiation using single-entry implants are based on the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol, which assumed a balloon implant geometry. We have developed robust plan evaluation criteria specifically for the strut-adjusted volume implant (SAVI). METHODS A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016