Surgical induced astigmatism correlated with corneal pachymetry and intraocular pressure: transconjunctival sutureless 23-gauge versus 20-gauge sutured vitrectomy in diabetes mellitus.
نویسندگان
چکیده
AIM To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intraocular pressure (IOP) on surgical induced astigmatism in diabetic patients. METHODS This retrospective, consecutive case series consisted of 40 eyes of 38 diabetic subjects who underwent either 20-gauge or 23-gauge vitrectomy. The corneal curvature and thickness were measured with Scheimpflug imaging before surgery and 1wk; 1, 3mo after surgery. We compared the surgical induced astigmatism (SIA) on the true net power in 23-gauge group with that in 20-gauge group. We determined the correlation between corneal thickness change ratio, IOP and SIA measured by Pentacam. RESULTS The mean SIAs were 1.082±0.085 D (mean±SEM), 0.689±0.070 D and 0.459±0.063 D at postoperative 1wk; 1, 3mo respectively in diabetic subjects. The vitrectomy induced astigmatisms were declined significantly with time (F 2,36=33.629, P=0.000) postoperatively. The 23-gauge surgery group induced significantly less astigmatism than 20-gauge surgery group (F -1,37=11.046, P=0.020). Corneal thickness in diabetes elevated after surgery (F 3,78=10.532, P=0.000). The linear regression analysis at postoperatively 1wk went as: SIA=-4.519+4.931 change ratio (Port3) +0.026 IOP (R(2)=0.46, P=0.000), whereas the rate of corneal thickness change and IOP showed no correlation with the change of astigmatism at postoperatively 1 and 3mo. CONCLUSION There are significant serial changes in both 20-gauge and 23-gauge group in diabetic subjects. 23-gauge induce less astigmatism than 20-gauge and become stable more rapidly than 20-gauge. The elevation of corneal thickness and IOP was associated with increased astigmatim at the early postoperative stage both in 23-gauge and 20-gauge surgery group.
منابع مشابه
Changes in Day 1 Post-Operative Intraocular Pressure Following Sutureless 23-Gauge and Conventional 20-Gauge Pars Plana Vitrectomy
BACKGROUND/AIMS The benefits associated with transconjunctival sutureless vitrectomy techniques are continuing to be defined. The purpose of this study was to compare the incidence of extreme changes in day 1 intraocular pressure (IOP) following 23-gauge sutureless vitrectomy compared with conventional 20-gauge vitrectomy. METHODS Fifty consecutive 23-gauge and 50 consecutive 20-gauge cases w...
متن کاملSutured Versus Sutureless Sclerotomies after 25 Gauge Vitrectomy without an Internal Tamponade
Objective: We wished to determine whether suturing of 25 gauge sclerotomies was advantageous in maintaining normal intraocular pressure (IOP) or preventing hypotony after 25-gauge vitrectomy in eyes not requiring internal tamponade. Methods: Two-hundred seventeen consecutive 25-gauge vitrectomy surgeries from 2010 to 2013 performed at a single center by two surgeons were retrospectively reviewe...
متن کاملOutcomes of transconjunctival sutureless 27-gauge micro-incision vitrectomy surgery in diabetic vitreous haemorrhage
OBJECTIVE To evaluate the visual outcomes of 27-gauge transconjunctival sutureless vitrectomy surgery and its complications in patients with diabetic vitreous hemorrhage. METHODS A quasi-experimental study was conducted where eighty seven eyes of 87 uncontrolled type II diabetes mellitus patients presenting with diabetic vitreous hemorrhage were selected to undergo 27-gauge transconjunctival ...
متن کاملTwenty five-gauge sutureless vitrectomy versus 20-gauge vitrectomy in epiretinal membrane surgery.
PURPOSE To compare visual outcomes, intraoperative and postoperative complications of 25-gauge transconjunctival sutureless vitrectomy (25-G TSV) versus conventional 20-gauge vitrectomy in epiretinal membrane (ERM) surgery. METHODS A retrospective comparative study was conducted on 200 eyes with idiopathic ERM who underwent either primary 20-gauge vitrectomy (n=95) or 25-G TSV (n=105) with 6 ...
متن کاملActive Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?
OBJECTIVES To evaluate the safety and efficacy of active silicone oil removal with a 23-gauge (G) transconjunctival sutureless system. MATERIALS AND METHODS One hundred sixteen eyes of 113 patients who had previous retinal detachment surgery with pars plana vitrectomy and silicone oil injection surgery, and underwent silicone oil removal surgery with 23-G transconjonctival sutureless techniqu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2015