Algometry with a clothes peg compared to an electronic pressure algometer: a randomized cross-sectional study in pain patients

نویسندگان

  • Niklaus Egloff
  • Nicole Klingler
  • Roland von Känel
  • Rafael JA Cámara
  • Michele Curatolo
  • Barbara Wegmann
  • Elizabeth Marti
  • Marie-Louise Gander Ferrari
چکیده

BACKGROUND Hypersensitivity of the central nervous system is widely present in pain patients and recognized as one of the determinants of chronic pain and disability. Electronic pressure algometry is often used to explore aspects of central hypersensitivity. We hypothesized that a simple pain provocation test with a clothes peg provides information on pain sensitivity that compares meaningfully to that obtained by a well-established electronic pressure algometer. "Clinically meaningful" was defined as a medium (r = 0.3-0.5) or high (r > 0.5) correlation coefficient according to Cohen's conventions. METHODS We tested 157 in-patients with different pain types. A calibrated clothes peg was applied for 10 seconds and patients rated the pain intensity on a 0 to 10 numerical rating scale. Pressure pain detection threshold (PPdt) and pressure pain tolerance threshold (PPtt) were measured with a standard electronic algometer. Both methods were performed on both middle fingers and ear lobes. In a subgroup of 47 patients repeatability (test-retest reliability) was calculated. RESULTS Clothes peg values correlated with PPdt values for finger testing with r = -0.54 and for earlobe testing with r = -0.55 (all p-values < 0.001). Clothes peg values also correlated with PPtt values for finger testing with r = -0.55 (p < 0.001). Test-retest reliability (repeatability) showed equally stable results for clothes peg algometry and the electronic algometer (all r-values > 0.89, all p-values < 0.001). CONCLUSIONS Information on pain sensitivity provided by a calibrated clothes peg and an established algometer correlate at a clinically meaningful level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in Pain Processing Between Patients with Chronic Low Back Pain, Recurrent Low Back Pain, and Fibromyalgia.

BACKGROUND The impairment in musculoskeletal structures in patients with low back pain (LBP) is often disproportionate to their complaint. Therefore, the need arises for exploration of alternative mechanisms contributing to the origin and maintenance of non-specific LBP. The recent focus has been on central nervous system phenomena in LBP and the pathophysiological mechanisms underlying the var...

متن کامل

Dynamic mechanical assessment of muscle hyperalgesia in humans: The dynamic algometer

BACKGROUND Musculoskeletal pain is often associated with a nonhomogeneous distribution of mechanical hyperalgesia. Consequently, new methods able to detect this distribution are needed. OBJECTIVE To develop and test a new method for assessing muscle hyperalgesia with high temporal and spatial resolution that provides complementary information compared with information obtained by traditional ...

متن کامل

Algometry to measure pain threshold in the horse’s back – An in vivo and in vitro study

BACKGROUND The aim of this study was to provide information on algometric transmission of pressure through the dorsal thoracolumbar tissues of the equine back. Using a commercially available algometer, measurements were carried out with six different tips (hemispheric and cylindrical surfaces, contact areas 0.5 cm2, 1 cm2, and 2 cm2). In nine live horses the threshold of pressure that lead to a...

متن کامل

Interrater reliability of algometry in measuring pressure pain thresholds in healthy humans, using multiple raters.

OBJECTIVE To evaluate interrater reliability using 5 newly trained observers in the assessment of pressure pain threshold (PPT) using a fixed-angle algometer. METHODS The study design comprised 2 phases. Phase 1: 5 undergraduate physical therapists were trained in algometry at a predefined angle, at a rate of 5 Newtons (N)/s, to the first dorsal interosseous muscle. Each observer then underwe...

متن کامل

Is bone tenderness, as measured by manual algometry, associated with vitamin D deficiency?

OBJECTIVE To explore the relationship between serum 25-hydroxycholecalciferol (25[OH]D3) and pressure-pain thresholds, as measured by algometer, in advance of a main study to determine whether PPT is a potentially cost-effective proxy measure of 25[OH]D3 status in the general population. METHODS The cross-sectional pilot study involved a convenience sample of twenty-two subjects (10 males, 12...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011