BACKGROUND the characteristics of (90)Y, suitable for therapy, are denoted by the lack of γ-emission. Alternative methods, using analogues labelled with (111)In or (86)Y, are generally applied to image (90)Y-conjugates, with some inevitable drawbacks. New generation SPECT/CT image systems offer improved Bremsstrahlung images. The intent of this brief communication is to show that high quality (90)Y-Bremsstrahlung SPECT-CT images can be obtained, allowing the biodistribution of pure β-emitter therapeutical agents to be evaluated, also during the course of therapy. METHODS the hybrid system Siemens Symbia-T2 was used for the acquisition of images of a patient given 1.7 GBq of (90)Y-DOTATATE. The following parameters were set for SPECT: 80 (50%) and 120 (30%) keV energy windows; medium energy collimators; 128 × 128 matrix, 64 projections (40s/step). Low-dose CT was acquired (80 mAs) for attenuation correction. Images were reconstructed with the OSEM 3D-Fast algorithm. RESULTS post-therapy SPECT-CT (90)Y-Bremsstrahlung images of a patient undergoing receptor peptide radionuclide therapy are presented. (90)Y-Bremsstrahlung images obtained are suitable for tumour and normal organ dosimetry, providing detailed information on biodistribution, comparable to (111)In-diagnostic images. CONCLUSIONS the improved Bremsstrahlung images means that the diagnostic examinations can be used for patient recruitment and that dosimetry evaluation can be restricted only to treated patients. This could avoid the need for a different radionuclide or isotope to mimic therapy. The clinical impact might be notable, as dosimetry and toxicity information are essential in radionuclide therapy, especially in patients with risk factors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of Bremsstrahlung imaging in Yttrium internal radiation therapy

Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...

متن کامل

Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

متن کامل

Comparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study

Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simu...

متن کامل

The Impact of Image Reconstruction Bias on PET/CT 90Y Dosimetry After Radioembolization

PET/CT imaging after radioembolization is a viable method for determining the posttreatment 90Y distribution in the liver. Low true-torandom coincidence ratios in 90Y PET studies limit the quantitative accuracy of these studies when reconstruction algorithms optimized for traditional PET imaging are used. This study examined these quantitative limitations and assessed the feasibility of generat...

متن کامل

Phantom and clinical evaluation of the effect of full Monte Carlo collimator modelling in post-SIRT yttrium-90 Bremsstrahlung SPECT imaging

BACKGROUND Post-therapy SPECT/CT imaging of 90Y microspheres delivered to hepatic malignancies is difficult, owing to the continuous, high-energy Bremsstrahlung spectrum emitted by 90Y. This study aimed to evaluate the utility of a commercially available software package (HybridRecon, Hermes Medical Solutions AB) which incorporates full Monte Carlo collimator modelling. Analysis of image qualit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008