Interaction of intraluminal tissue and coronary sinus lead stabilized with stent placement.

نویسندگان

  • Tibor Balázs
  • Béla Merkely
  • Eszter Bognár
  • Endre Zima
چکیده

INTRODUCTION The aim of our investigation was to examine the intraluminal interaction of the vascular tissue and the implanted coronary sinus lead stabilized with stent on two human hearts removed before transplantation. METHODS AND RESULTS The coronary sinus lumen was sectioned under operational microscope and opened carefully. The leads and stents were found separately positioned beside each other completely covered by an intact intimal tissue layer. No sign of occluding proliferative tissue was observed. CONCLUSION Stent fixation technique and extraction of the CS lead in our cases did not have any particular damaging effect on the vascular system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulated extraction of stent stabilized coronary sinus leads

Cardiac resynchronization therapy (CRT) is an effective nonpharmacological therapeutic method for the treatment of selected patients with chronic heart failure with a wide QRS complex and mechanical dyssynchrony of cardiac ventricles. A new technique is used to stabilize the implanted coronary sinus lead in an appropriate position with an expanded coronary stent to maintain synchronous pacing o...

متن کامل

CT virtual endoscopy and 3D stereoscopic visualisation in the evaluation of coronary stenting

The aim of this case report is to present the additional value provided by CT virtual endoscopy and 3D stereoscopic visualisation when compared with 2D visualisations in the assessment of coronary stenting. A 64-year old patient was treated with left coronary stenting 8 years ago and recently followed up with multidetector row CT angiography. An in-stent restenosis of the left coronary artery w...

متن کامل

Rescue-stenting of an occluded lateral coronary sinus branch for recanalization after dissection during cardiac resynchronization device implantation.

Cardiac resynchronization therapy (CRT) using left- (LV) or biventricular pacing is widely applied in selected heart failure patients. However, transvenous LV-lead placement into coronary sinus (CS) branches can be challenging. A 77-year-old female patient with New York Heart Association class III symptoms due to dilated cardiomyopathy [LV ejection fraction (LVEF): 10%, QRS-duration: 150 ms], d...

متن کامل

Optimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique

Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...

متن کامل

Intra Vascular Ultrasound in Coronary Syndromes: an Overview

fHE CONVENTIONAL coronary angiogram provides :letails of the lumen of the coronary arteries. The mgiogram, however, does not provide information of the structure of the intima, media, and adventitia. With intracoronary ultrasound probes, it is possible to directly obtain information not only of the coronary lumen but also of the type of intraluminal structures and to differentiate cholesterol f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 24 4  شماره 

صفحات  -

تاریخ انتشار 2013