CdZnTe spectra improvement through digital pulse amplitude correction using the linear sliding method
نویسندگان
چکیده
This paper presents innovative algorithms for optimum filtering, rise-time discrimination and proper correction of solid-state detector pulses based on digital pulse processing (DPP) techniques and on a Linear Sliding Method. These techniques allow a significant improvement on the spectral resolution by taking into account both the electronic noise and the pulse rise time fluctuations mainly due to the incomplete charge collection in the CZT crystal. In order to develop these algorithms pre-amplified pulses coming from a planar XR100-T detector (Amptek) were digitized by a 12bit PCI acquisition card (125MHz) hosted by a PC platform. The presented results show that, due to the possibility of fine adjustments on the discrimination and correction parameters during the processing stage, this flexible DPP implementation leads to significantly better results than the analog hardware discrimination solution. Comparative analysis of Am-241 spectra show a significant reduction of the low-energy ‘‘tail’’ on the 59.5 keV photo-peak. r 2003 Elsevier Science B.V. All rights reserved. PACS: 07.05.Hd; 84.30.Sk; 07.50.Qx; 02.70.Hm
منابع مشابه
Improvement of Energy Characteristics of Semiconductor Detectors Using Genetic Algorithms
A new charge loss correction method using genetic algorithms (GA) has been proposed to improve gamma ray energy spectrum characteristics of CdZnTe detectors. The correction method is based on the analysis of signal waveform shapes. GA recognizes the charge generation places for each signal and provides the related corrective factors of the pulse heights; the corrected energy spectrum was obtain...
متن کاملPulse-height loss in the signal readout circuit of compound semiconductor detectors
Compound semiconductor detectors such as CdTe, CdZnTe, HgI2 and TlBr are known to exhibit large variations in their charge collection times. This paper considers the effect of such variations on the measurement of induced charge pulses by using resistive feedback charge-sensitive preamplifiers. It is shown that, due to the finite decaytime constant of the preamplifiers, the capacitive decay dur...
متن کاملMEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR
INTRODUCTION We directly measured diagnostic X-ray photon spectra produced by a single-phase 2-pulse diagnostic X-ray unit driven at 50 to 100 kV and a few mA(1), a mammographic X-ray unit at 25 to 32 kV and 3 times of 80 mAs(2) and an X-ray computed tomography (CT) scanner at 120 kV and 3 mA(3) have been analyzed. Since detected spectra were distorted by the response of CdZnTe(CZT) detector an...
متن کاملAngular response of a W-collimated room-temperature-operated CdZnTe Frisch collar spectrometer
The spatial resolution of a collimated CdZnTe Frisch collar detector was experimentally investigated for two different tungsten collimator designs using a Au gamma-ray source at 412 keV. A two-dimensional model for the detector–collimator–source geometry was developed and applied with some simplifying assumptions. The CdZnTe detector was fabricated from a single crystal using a copper shim as t...
متن کاملImprovement Performances of Active and Reactive Power Control Applied to DFIG for Variable Speed Wind Turbine Using Sliding Mode Control and FOC
This paper deals with the Active and Reactive Power control of double-fed induction generator (DFIG) for variable speed wind turbine. For controlling separately the active and the reactive power generated by a DFIG, field oriented control (FOC) and indirect sliding mode control (ISMC) are presented. These non linear controls are compared on the basis of topology, cost, efficiency. The main cont...