Completely automated open-path FT-IR spectrometry.

نویسندگان

  • Peter R Griffiths
  • Limin Shao
  • April B Leytem
چکیده

Atmospheric analysis by open-path Fourier-transform infrared (OP/FT-IR) spectrometry has been possible for over two decades but has not been widely used because of the limitations of the software of commercial instruments. In this paper, we describe the current state-of-the-art of the hardware and software that constitutes a contemporary OP/FT-IR spectrometer. We then describe advances that have been made in our laboratory that have enabled many of the limitations of this type of instrument to be overcome. These include not having to acquire a single-beam background spectrum that compensates for absorption features in the spectra of atmospheric water vapor and carbon dioxide. Instead, an easily measured "short path-length" background spectrum is used for calculation of each absorbance spectrum that is measured over a long path-length. To accomplish this goal, the algorithm used to calculate the concentrations of trace atmospheric molecules was changed from classical least-squares regression (CLS) to partial least-squares regression (PLS). For calibration, OP/FT-IR spectra are measured in pristine air over a wide variety of path-lengths, temperatures, and humidities, ratioed against a short-path background, and converted to absorbance; the reference spectrum of each analyte is then multiplied by randomly selected coefficients and added to these background spectra. Automatic baseline correction for small molecules with resolved rotational fine structure, such as ammonia and methane, is effected using wavelet transforms. A novel method of correcting for the effect of the nonlinear response of mercury cadmium telluride detectors is also incorporated. Finally, target factor analysis may be used to detect the onset of a given pollutant when its concentration exceeds a certain threshold. In this way, the concentration of atmospheric species has been obtained from OP/FT-IR spectra measured at intervals of 1 min over a period of many hours with no operator intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advances in data processing for open-path Fourier transform infrared spectrometry of greenhouse gases.

The automated quantification of three greenhouse gases, ammonia, methane, and nitrous oxide, in the vicinity of a large dairy farm by open-path Fourier transform infrared (OP/FT-IR) spectrometry at intervals of 5 min is demonstrated. Spectral pretreatment, including the automated detection and correction of the effect of interrupting the infrared beam, is by a moving object, and the automated c...

متن کامل

Information extraction from a complex multicomponent system by target factor analysis.

A theoretical investigation into the mechanism of information extraction by target factor analysis (TFA) is presented from experimental data in the form of a matrix, and the results were validated using composite spectra obtained by open-path Fourier transform-infrared (FT-IR) spectrometry. The composite spectra were generated by adding the spectral information of a target molecule with known p...

متن کامل

Correcting nonlinear response of mercury cadmium telluride detectors in open path Fourier transform infrared spectrometry.

The effect of a nonlinear response of mercury cadmium telluride (MCT) detectors to photon flux is to cause a large offset and a slow variation in the zero-line of single-beam Fourier transform infrared (FT-IR) spectra, which dramatically reduce the accuracy to which strongly absorbing bands or lines can be measured. We describe a noniterative numerical technique by which the baseline offset can...

متن کامل

Detection of chemical agents in the atmosphere by open-path FT-IR spectroscopy under conditions of background interference: II. Fog and rain.

Open-path FT-IR spectra of low-concentration releases of diethyl ether were measured both when a glycol fog was passed into the infrared beam and when large water droplets from a lawn sprinkler were sprayed into the beam. It was shown that the glycol fog, for which the droplet size was much less than the wavelength of the infrared radiation, gave rise to a significant interference such that par...

متن کامل

Increasing the quantitative credibility of open-path Fourier transform infrared (FT-IR) spectroscopic data, with focus on several properties of the background spectrum.

The choice of the type of background spectrum affects the credibility of open-path Fourier transform infrared spectroscopy (OP/FT-IR) data, and consequently, the quality of data analysis. We systematically investigated several properties of the background spectrum. The results show that a short-path background measured with the lowest amplifier gain could significantly reduce noise in the calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 393 1  شماره 

صفحات  -

تاریخ انتشار 2009