Rapid plasma reagin card test: evaluation of a hand-rotation procedure and stability of the RPR antigen.
نویسندگان
چکیده
Reported are the results of a comparative study of two procedures for the rapid plasma reagin (RPR) test for syphilis serology: in one approach a mechanical rotator was used and in the other, hand rotation was employed. Both procedures were performed on 327 sera. The agreement between both was 98.8%. Three sera that exhibited minimal reactivity (titre = 1) in the mechanical-rotation RPR were nonreactive in the hand-rotation RPR. RPR antigen was stored for 3 months at room temperature (mean, 21 degrees C) and 30 degrees C. There was no difference in the reactivity of 62 sera (50 positive, 12 negative) that were tested using either adversely stored antigens or antigen stored at 4 degrees C. In poorly equipped settings at the primary health care level, the hand-rotation RPR is a practical alternative to mechanical rotation. Also, the stability of the antigen under adverse storage conditions is an additional advantage of RPR for use in tropical areas.
منابع مشابه
Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.
The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Bec...
متن کاملEvaluation of NCS rapid plasma reagin card test, a new screening kit for syphilis.
Agreements in qualitative and quantitative test results between the recently marketed NCS rapid plasma reagin card test (NCS Diagnostics Corp.) and the Macro-Vue rapid plasma reagin 18-mm circle card test (Hynson, Westcott and Dunning) were 99.2 and 99.1%, respectively, indicating the NCS RPR card test to be an acceptable alternative procedure for the serodiagnosis of syphilis.
متن کاملEvaluation of a new rapid plasma reagin card test as a screening test for syphilis.
This study evaluates the American Dade (Biokit Laboratories) rapid plasma reagin (Dade RPR) card test, currently used in Spain for the diagnosis of syphilis, which has been recently released to the U.S. market. Used as a basis for comparison with the Dade card test were the 18-mm standard rapid plasma reagin (standard RPR) card test and the Venereal Disease Research Laboratory (VDRL) slide test...
متن کاملInterlaboratory comparison of the toluidine red unheated serum test antigen preparation.
The toluidine red unheated serum test (TRUST) antigen, a macroscopic flocculation test antigen developed by Pettit et al. (J. Clin. Microbiol. 18:1141-1145, 1983) by modifying the color-coded antigen of Kasatiya and Lambert (Appl. Microbiol. 28:317-318, 1974), was compared with the Venereal Disease Research Laboratory (VDRL) slide and rapid plasma reagin (RPR) 18-mm circle card tests for sensit...
متن کاملRapid plasma reagin (RPR) card test. A screening method for treponemal disease.
The specific FTA-ABS and TPI tests are too costly and time-consuming to be used as screening procedures for treponemal disease. The VDRL test detects reagin, the antibody amongst others produced in syphilis and yaws and also present in a wide variety of disorders giving the biological false positive reaction. The RPR card test (Portnoy, Garson, and Smith, 1957; Reed, 1965), like the VDRL test, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of the World Health Organization
دوره 72 5 شماره
صفحات -
تاریخ انتشار 1994