Image distortion correction in EPI: comparison of field mapping with point spread function mapping.
نویسندگان
چکیده
Echo-planar imaging (EPI) can provide rapid imaging by acquiring a complete k-space data set in a single acquisition. However, this approach suffers from distortion effects in geometry and intensity, resulting in poor image quality. The distortions, caused primarily by field inhomogeneities, lead to intensity loss and voxel shifts, the latter of which are particularly severe in the phase-encode direction. Two promising approaches to correct the distortion in EPI are field mapping and point spread function (PSF) mapping. The field mapping method measures the field distortions and translates these into voxel shifts, which can be used to assign image intensities to the correct voxel locations. The PSF approach uses acquisitions with additional phase-encoding gradients applied in the x, y, and/or z directions to map the 1D, 2D, or 3D PSF of each voxel. These PSFs encode the spatial information about the distortion and the overall distribution of intensities from a single voxel. The measured image is the convolution of the undistorted density and the PSF. Measuring the PSF allows the distortion in geometry and intensity to be corrected. This work compares the efficacy of these methods with equal time allowed for field mapping and PSF mapping.
منابع مشابه
Point spread function mapping for distortion correction of spinal cord diffusion weighted MRI
Introduction Diffusion Weighted Magnetic Resonance Imaging (DWMRI) is a promising method to assess axonal integrity in the spinal cord in vivo [1]. However, the fast imaging sequences required for in vivo DWMRI are sensitive to B0-field inhomogeneities caused by susceptibility differences around vertebral structures and lungs. Those inhomogeneities cause voxel shift that corrupt the anatomical ...
متن کاملAccelerated Point Spread Function Mapping Using Compressed Sensing for EPI Geometric Distortion Correction
Introduction: Single-shot echo-planar imaging (EPI) is a fast technique allowing the acquisition of an image following a single RF excitation. The high temporal resolution of EPI makes it the method of choice for applications such as fMRI or diffusion tensor imaging. However, EPI is prone to geometric and intensity distortions in the presence of magnetic field inhomogeneities. Several correctio...
متن کاملComparison of EPI Distortion Correction Methods in Diffusion Tensor MRI Using a Novel Framework
Diffusion weighted images (DWIs) are commonly acquired with Echo-planar imaging (EPI). B0 inhomogeneities affect EPI by producing spatially nonlinear image distortions. Several strategies have been proposed to correct EPI distortions including B0 field mapping (B0M) and image registration. In this study, an experimental framework is proposed to evaluation the performance of different EPI distor...
متن کاملHighly accelerated Point-Spread Function mapping based on Finite Rate of Innovation for EPI distortion correction
Institute of Biophysics and Biomedical Engineering, Faculty of Sciences, University of Lisbon, Lisbon, Portugal Hybrid MR-PET scans enable acquisition of both types of images within a session. Despite consistent subject positioning, image alignment can still be challenging. Functional MR images rely on echo-planar imaging (EPI) and present geometric distortions due to static B0 field inhomogene...
متن کاملComparison of EPI Distortion Correction Methods in Diffusion Tensor MRI
Introduction Diffusion weighted images (DWIs) used for Diffusion Tensor (DT) calculation are commonly acquired with Echo-planar imaging (EPI). Unfortunately, EPI is very sensitive to magnetic field (B0 ) inhomogeneities, which result in local geometric distortions in regions close to air-tissue interfaces. These distortions degrade the anatomical accuracy of DT-MRI maps and potentially increase...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 48 1 شماره
صفحات -
تاریخ انتشار 2002