High-dose 7-hexanoyltaxol-eluting stent with polymer sleeves for coronary revascularization: one-year results from the SCORE randomized trial.

نویسندگان

  • Eberhard Grube
  • Alexandra Lansky
  • Karl Eugen Hauptmann
  • Carlo Di Mario
  • Germano Di Sciascio
  • Antonio Colombo
  • Sigmund Silber
  • Juergen Stumpf
  • Nicolaus Reifart
  • Jean Fajadet
  • Antonio Marzocchi
  • Joachim Schofer
  • Pierre Dumas
  • Rainer Hoffmann
  • Giulio Guagliumi
  • Mark Pitney
  • Mary E Russell
چکیده

OBJECTIVES The Study to COmpare REstenosis Rate between QueST and QuaDDS-QP2 (SCORE) trial was a multicenter, randomized, open-label trial comparing the safety and performance of 13- and 17-mm QuaDDS stents (n = 126) (Quanam Medical Corp., Santa Clara, California/Boston Scientific Corp., Natick, Massachusetts) versus uncoated control stents (n = 140) in focal, de novo coronary lesions. BACKGROUND The pioneering drug-delivery QuaDDS stent used four to six acrylate polymer sleeves, each loaded with 800 microg of the paclitaxel derivative 7-hexanoyltaxol. METHODS Clinical end points were assessed at 1, 6, and 12 months post procedure. Quantitative coronary angiography and intravascular ultrasound were performed post procedure and at six-month follow-up. RESULTS In the QuaDDS group, early stent thrombosis and myocardial infarction (MI) rates were significantly higher, leading to premature cessation of enrollment. For the QuaDDS group, the stent thrombosis rate increased from 3.2% to 10.3% between 1 and 12 months, associated with increased non-Q-wave MI and death rates. The angiographic restenosis rate at six months was reduced from 32.7% (control) to 7.4% (p < 0.0001). However, the primary end point was not met with six-month target vessel revascularization (TVR) rate as well as the composite major adverse cardiac event rates (cardiac death, MI, and TVR) comparable between groups. CONCLUSIONS Despite angiographic indications of potential anti-restenotic benefit, increased rates of stent thrombosis, MI, and cardiac death associated with the QuaDDS stent show an unacceptable safety profile.

منابع مشابه

Coated stents to prevent restenosis in coronary heart disease

BACKGROUND In-stent-restenosis (ISR) is considered to be an essential limiting factor of stenting in coronary heart disease (CHD). The development of coated stents has raised expectations on substantial lowering restenosis after stenting with decreasing the rate of restenosis and a reduction in the rate of clinical events. OBJECTIVES The present analysis addresses the questions on medical eff...

متن کامل

SYNTAX score and Clinical SYNTAX score as predictors of very long-term clinical outcomes in patients undergoing percutaneous coronary interventions: a substudy of SIRolimus-eluting stent compared with pacliTAXel-eluting stent for coronary revascularization (SIRTAX) trial.

AIMS To investigate the ability of SYNTAX score and Clinical SYNTAX score (CSS) to predict very long-term outcomes in an all-comers population receiving drug-eluting stents. METHODS AND RESULTS The SYNTAX score was retrospectively calculated in 848 patients enrolled in the SIRolimus-eluting stent compared with pacliTAXel-Eluting Stent for coronary revascularization (SIRTAX) trial. The CSS was...

متن کامل

First clinical experience with a paclitaxel derivate-eluting polymer stent system implantation for in-stent restenosis: immediate and long-term clinical and angiographic outcome.

BACKGROUND It has been shown that antiproliferative drugs such as paclitaxel lower the amount of intimal hyperplasia after stent implantation. We report the first clinical experience of 7-hexanoyltaxol (QP2)-eluting polymer stent system (QuaDS) implantation for in-stent restenosis. METHODS AND RESULTS Fifteen consecutive patients with elective indication to percutaneous coronary intervention ...

متن کامل

Interventional Cardiology Comparison of Everolimus-Eluting and Sirolimus-Eluting Coronary Stents 1-Year Outcomes from the Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET)

Background—Several recent randomized trials comparing everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) reported similar outcomes. However, only 1 trial was powered for a clinical end point, and no trial was powered for evaluating target-lesion revascularization. Methods and Results—Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial is a prospective ...

متن کامل

One-Year Clinical Results With the Slow-Release, Polymer-Based, Paclitaxel-Eluting TAXUS Stent

Background—The safety and efficacy of the slow-release, polymer-based, paclitaxel-eluting stent after implantation in a broad cross section of de novo coronary lesions at 1 year are unknown. Methods and Results—In the TAXUS-IV trial, 1314 patients with single de novo coronary lesions 10 to 28 mm in length, with reference-vessel diameter 2.5 to 3.75 mm, coverable by a single study stent, were pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 44 7  شماره 

صفحات  -

تاریخ انتشار 2004