Dual Energy X-Ray Absorptiometry Body Composition Reference Values from NHANES
نویسندگان
چکیده
In 2008 the National Center for Health Statistics released a dual energy x-ray absorptiometry (DXA) whole body dataset from the NHANES population-based sample acquired with modern fan beam scanners in 15 counties across the United States from 1999 through 2004. The NHANES dataset was partitioned by gender and ethnicity and DXA whole body measures of %fat, fat mass/height(2), lean mass/height(2), appendicular lean mass/height(2), %fat trunk/%fat legs ratio, trunk/limb fat mass ratio of fat, bone mineral content (BMC) and bone mineral density (BMD) were analyzed to provide reference values for subjects 8 to 85 years old. DXA reference values for adults were normalized to age; reference values for children included total and sub-total whole body results and were normalized to age, height, or lean mass. We developed an obesity classification scheme by using estabbody mass index (BMI) classification thresholds and prevalences in young adults to generate matching classification thresholds for Fat Mass Index (FMI; fat mass/height(2)). These reference values should be helpful in the evaluation of a variety of adult and childhood abnormalities involving fat, lean, and bone, for establishing entry criteria into clinical trials, and for other medical, research, and epidemiological uses.
منابع مشابه
Development of equations and proposed reference values to estimate body fat mass among Chilean children and adolescents.
INTRODUCTION The assessment of body composition is relevant to establish nutritional status and identify potential health risks. OBJETIVE a) To develop regression equations to predict fat mass (FM) using a dual-energy X-ray absorptiometry as reference method; b) to propose reference FM values based on chronological and biological age for Chilean children and adolescents. METHODOLOGY Cross-s...
متن کاملComparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus
The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...
متن کاملComparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis
Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...
متن کاملDevelopment and comparison of two field-based body fat prediction equations: NHANES 1999 – 2004
Clinical guidelines define obesity in terms of excess body weight adjusted for height (i.e., bodymass index [BMI] categories) and/or gender-specific waist circumference (WC) cut-point values. Since body composition, particularly fat mass, is the most variable among individuals due to differences by gender, age, and race, and total percent body fat (%BF) can be estimated accurately using dual-en...
متن کاملReference Values of Body Composition Indices: The Korean National Health and Nutrition Examination Surveys
PURPOSE An increase in the prevalence of obesity has been observed in children and adolescents. As remarkable changes in body composition occur with growth during the adolescent period, it is important that changes in body composition be monitored. The purpose of this study was to propose reference percentile values for body composition indices including body mass index (BMI) in children and ad...
متن کامل