Case-control study of surgical site infections associated with pacemakers and implantable cardioverter-defibrillators.
نویسندگان
چکیده
OBJECTIVE In 2000, the rate of surgical site infections (SSIs) associated with pacemaker and implantable cardioverter-defibrillator (ICD) procedures performed in the cardiothoracic operating rooms of hospital A was 16% (19 of 116 procedures resulted in infections). This study investigates risks for SSI associated with these procedures in the cardiothoracic operating room. DESIGN Unmatched 1 : 3 case-control study performed over a 12-month period among patients who had undergone implantation of a pacemaker and/or ICD. A standardized observation scrutinized infection control practices in the area where the procedures were performed. SETTING The cardiothoracic operating rooms of hospital A, which belongs to a hospital consortium in the midwestern United States. PATIENTS Patients with SSI were identified as case patients. Control patients were chosen from the group of uninfected patients who had procedures performed during the same period as case patients. RESULTS A total of 19 SSIs associated with pacemaker and ICD procedures were retrospectively identified among the patients who underwent procedures in these cardiothoracic operating rooms. Culture samples were obtained from 7 patients; 2 yielded coagulase-negative Staphylococcus on culture, 2 yielded Staphylococcus aureus, 1 yielded Serratia marcescens, and 2 showed no growth. In the case-control study, age, race, sex, diabetes mellitus, smoking history, timing of antibiotic therapy, and hair removal did not differ significantly between case patients and control patients. Case patients were more likely to have an abdominal device in place (odds ratio [OR], 5.5 [95% confidence interval {CI}, 1.6-19.3]; P=.006) and less likely to have received a new implant (OR 0.3 [95% CI, 0.1-0.8]; P=.02) or to have had new leads placed (OR, 0.2 [95% CI, 0.1-0.6]; P=.003). CONCLUSIONS Abdominal placement of implanted devices was associated with occurrence of an SSI after pacemaker and/or ICD procedures.
منابع مشابه
Erosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملStaphylococcus aureus bacteremia in patients with permanent pacemakers or implantable cardioverter-defibrillators.
BACKGROUND Although cardiac device infections (CDIs) are a devastating complication of permanent pacemakers or implantable cardioverter-defibrillators, the incidence of CDI in patients with bacteremia is not well defined. The objective of this study was to determine the incidence of CDI among patients with permanent pacemakers or implantable cardioverter-defibrillators who develop Staphylococcu...
متن کاملRisk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study.
BACKGROUND The Prospective Evaluation of Pacemaker Lead Endocarditis study is a multicenter, prospective survey of the incidence and risk factors of infectious complications after implantation of pacemakers and cardioverter-defibrillators. METHODS AND RESULTS Between January 1, 2000, and December 31, 2000, 6319 consecutive recipients of implantable systems were enrolled at 44 medical centers ...
متن کاملSafety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.
Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...
متن کاملIrradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience.
AIMS AND BACKGROUND A prospective analysis was carried out on a group of irradiated patients with pacemakers or implantable cardioverter-defibrillators to identify any relationship between the various types of devices and physical and dosimetric parameters. Cardiac toxicity of the treatment was also investigated. METHODS AND STUDY DESIGN Forty-five irradiated patients, implanted with pacemake...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Infection control and hospital epidemiology
دوره 28 11 شماره
صفحات -
تاریخ انتشار 2007