Utility and drawbacks of continuous use of a copper T IUD for 20 years.

نویسنده

  • Irving Sivin
چکیده

This article examines interrelated questions concerning the extent of need for contraception in women 40 years and older and the degree to which that need can be served when use of collared T IUDs is initiated in women aged 25-35 years. Differentials in the impacts of intrauterine device (IUD) use on health issues in the second decade of contraception are also addressed. Although fertility of all women aged 40-44 years is below 100 per 1000 in all regions of the world today, the risk of pregnancy among married or cohabiting women who do not use contraception is estimated at 270-300 per 1000 or 27-30% per year. At ages 45-49 years, the annual risk of pregnancy to women in union who do not use contraception lies at or above 10% per year. Data from three studies show that users of collared copper IUDs who continued using the same device beyond the completion of 10 years experienced no pregnancies through the end of 15 years. A small number of women continued with the same IUD through 20 years and still experienced no pregnancies. Use of collared copper T IUDs beyond 10 years was not associated with intensification of side effects nor with an increase in the relative frequency of those effects, with the exception of the experience of perimenopausal symptoms and problems. Neither increased bleeding nor increased severity of pelvic disease was manifest in the second decade of continuous use of the same IUD, as compared with the first decade of such use. Under our current understanding of the duration of IUD effectiveness, only a small percentage of women complete 10 years of use. Even with revised understanding of the duration of effectiveness of long-acting copper devices, average annual continuation rates must be quite high in order that 20% of women aged 25-35 years initiate a second decade of continuous IUD use. Those who do so would find considerable protection against pregnancy and reasonable economic benefits in continuing to use the same device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lack of association between CU T-380A intrauterine device and secondary infertility in Iran

Objective The appropriate choice of a contraceptive method has been a major issue in reproductive health research. Cu T intrauterine device (Cu T IUD) has been introduced as one of the most effective contraceptive methods in the world, however, the relationship between prior use of Cu T IUD and secondary infertility has not been evaluated in Iran. To examine the association of Cu T-380A IUD and...

متن کامل

P-170: Zinc and Copper Serum Level Alterations after An Intra Uterine Device Insertion

Background: Intra uterine devices (IUDs) are among the most commonly used contraception methods around the world. The most common form of IUDs used in Iran, is IUD Copper T-380A. As recently there is great emphasis on the role of blood zinc levels on general health conditions, this study was performed to assess the effects of IUD T-380-A insertion on zinc and also copper serum levels. Materials...

متن کامل

بررسی اثر کرم املا بر درد زمان جایگذاری آی یو دی مسی

  Background: One of the modern contraceptive methods is the insertion of intrauterine devices which contain copper and are effective for 12 years. One of the barriers to the use of IUDs, is fear from feeling pain during its insertion. EMLA cream 5% (25 mg of Lidocaine and 25 mg Prilocaine ) is a local anesthetic. The purpose of this study is to determine the effect of EMLA cream 5% on reducing...

متن کامل

Effects of IUD on iron status in IUD users in Gorgan, Iran

 Abstract Background: CuT380A intra uterine device Intra Uterine Device (IUD) is used in the health system of Iran. The most important and frequent side effects of the IUDs are hypermenorrhea and polymenorrhea. In Iran, iron supplement are not prescribed for the IUD users and there are no documents indicating their iron reservation status. This study was performed to determine the iron status i...

متن کامل

Prolonged intrauterine contraception: a seven-year randomized study of the levonorgestrel 20 mcg/day (LNg 20) and the Copper T380 Ag IUDS.

A levonorgestrel-releasing IUD and the Copper T 380Ag IUD were in randomized comparison for seven years in five clinics. In two other clinics the randomized study was truncated at five years, but use of the Copper T continued. No pregnancies occurred to users of either device in years 6 and 7. Cumulative pregnancy rates were 1.1 per 100 at seven years for the steroid-releasing and 1.4 per 100 f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contraception

دوره 75 6 Suppl  شماره 

صفحات  -

تاریخ انتشار 2007