A novel lens cleaner to prevent water drop adhesions during colonoscopy and esophagogastroduodenoscopy

نویسندگان

  • Naohisa Yoshida
  • Yuji Naito
  • Ritsu Yasuda
  • Takaaki Murakami
  • Kiyoshi Ogiso
  • Ryohei Hirose
  • Yutaka Inada
  • Osamu Dohi
  • Tetsuya Okayama
  • Kazuhiro Kamada
  • Kazuhiko Uchiyama
  • Takeshi Ishikawa
  • Osamu Handa
  • Hideyuki Konishi
  • Rafiz Abdul Rani
  • Yoshito Itoh
چکیده

Background and study aims  Water drop adhesions (WDA) impair endoscopic view during gastrointestinal endoscopy. We developed a novel lens cleaner designed using two types of harmLess surfactants and it is reported to be useful for preventing lens cloudiness during colorectal ESD. In the current study, we examined the ability of it for preventing and removing WDA. Patients and methods  During laboratory experiments, the cleaner (Cleash; Fujifilm Co., Tokyo, Japan and Nagase Medicals Co., Hyogo, Japan) was applied to the endoscopic lens and an air/water device (AWD) (water 200 mL, dimethicone 1 mL, Cleash 1 mL). The endoscope was submerged in water 100 times for 5 cycles. Rates of WDA were calculated for various groups (lens and AWD with or without Cleash) and compared to a normal cleaner (SL cleaner). During clinical research, 30 colonoscopies and 30 esophagogastroduodenoscopies were analyzed. For the Cleash group, the cleaner was applied to both lens and AWD. The numbers of WDA and WDA with non-rapid removal were calculated, compared to those of the SL cleaner group. Results  The mean WDA rate for the Cleash setting (lens: Cleash; AWD: Cleash) was 11.0 %, which was significantly lower than other settings (lens: SL cleaner; AWD: water, 31.0 %; P  < 0.001) (lens: Cleash; AWD: water, 19.0 %; P  < 0.001). Clinical research of colonoscopies indicated that the numbers of WDA (number/15 sec) and WDA with non-rapid removal were 0.38 and 0.17 for the Cleash group and 0.91 and 0.46 for the SL cleaner groups ( P  < 0.001, P  < 0.001). For esophagogastroduodenoscopies, the results were 0.47 and 0.24 for the Cleash group and 0.54 and 0.42 for the SL cleaner group ( P  = 0.72, P  = 0.018). Conclusion  A clear and beautiful image without WDA is useful not only for routine endoscopy but also, more importantly, for magnifying endoscopy and other endoscopic treatments. The use of Cleash to lens and AWD showed positive results for preventing and removing WDA during laboratory experiments and clinical research involving CS. Additionally, it also showed positive results for the removal of WDA during EGD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Splenic Injury after Elective Colonoscopy

Splenic injury is a rare but serious complication of colonoscopy. Since the mid-1970s, 68 splenic injuries during colonoscopy including our 2 cases have been described. With the increasing use of colonoscopy, endoscopists, surgeons, and radiologists are more likely to encounter this unusual complication. Any cause of increased splenocolic adhesions, splenomegaly, or underlying splenic disease m...

متن کامل

Effect Supermint oil (Peppermint oil) on the Patient's and Colonoscopy Team Satisfaction During Colonoscopy in Children

Introduction: Colonoscopy is an invasive method that is painful for patient especially for children. The objective of this research was investigation of the effect of supermint oral drop (peppermint essence) on the patient and colonoscopist group satisfaction during colonoscopy.    Materials and Methods: One hundred and one patient's candidate for colonoscopy was randomly divided into two group...

متن کامل

Effect Supermint oil (peppermint oil) on Patient Satisfaction and the Colonoscopy team during Colonoscopy

Introduction: Colonoscopy is an invasive method that is painful for patient especially for children. The objective of this research was investigation into the effect of supermint oral drop (peppermint essence) on the patient and colonoscopist group satisfaction during colonoscopy.   Material and Methods: In this clinical trial study, 101 children candidate colonoscopy (7-14 years old) in childr...

متن کامل

Management Options of Colonoscopic Splenic Injury

Injury to the spleen during routine colonoscopy is an extremely rare injury. Diagnosis and management of the injury has evolved with technological advances and experience gained in the management of splenic injuries sustained in trauma. Of the 37 reported cases of colonoscopic splenic injury, 12 had a history of prior surgery or a disease process suggesting the presence of adhesions. Only 6 had...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017