Powder diffraction in Bragg–Brentano geometry with straight linear detectors
نویسندگان
چکیده
A common way of speeding up powder diffraction measurements is the use of one- or two-dimensional detectors. This usually goes hand in hand with worse resolution and asymmetric peak profiles. In this work the influence of a straight linear detector on the resolution function in the Bragg-Brentano focusing geometry is discussed. Because of the straight nature of most modern detectors geometrical defocusing occurs, which heavily influences the line shape of diffraction lines at low angles. An easy approach to limit the resolution-degrading effects is presented. The presented algorithm selects an adaptive range of channels of the linear detector at low angles, resulting in increased resolution. At higher angles the whole linear detector is used and the data collection remains fast. Using this algorithm a well behaved resolution function is obtained in the full angular range, whereas using the full linear detector the resolution function varies within one pattern, which hinders line-shape and Rietveld analysis.
منابع مشابه
A diffracted-beam monochromator for long linear detectors in X-ray diffractometers with Bragg-Brentano parafocusing geometry.
A new diffracted-beam monochromator has been developed for Bragg-Brentano X-ray diffractometers equipped with a linear detector. The monochromator consists of a cone-shaped graphite highly oriented pyrolytic graphite crystal oriented out of the equatorial plane such that the parafocusing geometry is preserved over the whole opening angle of the linear detector. In our standard setup a maximum w...
متن کاملDivergence-slit intensity corrections for Bragg–Brentano diffractometers with circular sample surfaces and known beam intensity distribution
Author(s) of this paper may load this reprint on their own web site provided that this cover page is retained. Republication of this article or its storage in electronic databases or the like is not permitted without prior permission in writing from the IUCr. Bragg±Brentano powder diffractometers equipped with ®xed-divergence slits show a loss of intensity at small 2 angles as a result of the o...
متن کاملThe use of net analyte signal orthogonalization in the separation of multi-component diffraction patterns obtained from X-ray powder diffraction of intact compacts.
X-ray powder diffraction (XRPD) analysis of intact multi-component consolidated mixtures has significant potential owing to the ability to non-destructively quantify and discriminate between solid phases in composite bodies with minimal sample preparation. There are, however, limitations to the quantitative power using traditional univariate methods on diffraction data containing features from ...
متن کاملMicrostructure analysis of complex CuO/ZnO@carbon adsorbers: what are the limits of powder diffraction methods?
Activate carbon impregnated with a mixture of copper oxide and zinc oxide performs well as active adsorber for NO2 removal in automotive cabin air filters. The oxide-loaded activated carbon exhibits superior long-term stability in comparison to pure activated carbon as has been shown in previous studies. The carbon material was loaded only with 2.5 wt% of each metal oxide. Characterization of t...
متن کاملTHE IMPORTANCE OF THE SPECIMEN DISPLACEMENT CORRECTION IN RIETVELD PATTERN FITTING WITH SYMMETRIC REFLECTION-OPTICS DIFFRACTION DATA, B. O'Connor, D. Li, B. Hunter, pp. 96-102
Displacement of the specimen surface from the instrument rotation axis in reflection optics diffractometry introduces bias into the measured Bragg peak positions thereby causing systematic shifts in the 2θ-dependent Rietveld parameters. Specimen transparency also results in 2θ-bias, which tends to mimic that from specimen displacement. The authors have investigated the influence of specimen dis...
متن کامل