Reproducibility of different screening classifications in ultrasonography of the newborn hip

نویسندگان

  • Christian D Peterlein
  • Karl F Schüttler
  • Stefan Lakemeier
  • Nina Timmesfeld
  • Christian Görg
  • Susanne Fuchs-Winkelmann
  • Markus D Schofer
چکیده

BACKGROUND Ultrasonography of the hip has gained wide acceptance as a primary method for diagnosis, screening and treatment monitoring of developmental hip dysplasia in infants. The aim of the study was to examine the degree of concordance of two objective classifications of hip morphology and subjective parameters by three investigators with different levels of experience. METHODS In 207 consecutive newborns (101 boys; 106 girls) the following parameters were assessed: bony roof angle (α-angle) and cartilage roof angle (β-angle) according to Graf's basic standard method, "femoral head coverage" (FHC) as described by Terjesen, shape of the bony roof and position of the cartilaginous roof. Both hips were measured twice by each investigator with a 7.5 MHz linear transducer (SONOLINE G60S® ultrasound system, SIEMENS, Erlangen, Germany). RESULTS Mean kappa-coefficients for the subjective parameters shape of the bony roof (0.97) and position of the cartilaginous roof (1.0) demonstrated high intra-observer reproducibility. Best results were achieved for α-angle, followed by β-angle and finally FHC. With respect to limits of agreement, inter-observer reproducibility was calculated less precisely. CONCLUSIONS Higher measurement differences were evaluated more in objective scorings. Those variations were observed by every investigator irrespective of level of experience.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of ultrasonography in developmental dysplasia of the hip

PURPOSE Ultrasonography has been used as a diagnostic tool in developmental dysplasia of the hip (DDH) during early infancy since the early 1980s. The aim of this review article is to summarise the technique, benefits and shortcomings of four infantile hip ultrasonography methods, focusing mainly on the Graf method, and to assess the effectiveness of ultrasonographic newborn hip screening progr...

متن کامل

Evaluation of Different Risk Factors for Early Diagnosis of Diabetes Mellitus

Background: The efficacy of various screening variables in detection of diabetes mellitus (DM) is unclear. Objective: To determine the efficacy of various diagnostic tests for type 2 DM. Methods: 1021 inhabitants of Hakimieh district of Tehran aged between 30 and 75 years were studied.  Known cases of diabetes and those with factors influencing glucose tolerance test were excluded.  Age, sex, f...

متن کامل

Ultrasonography in screening for developmental dysplasia of the hip in newborns: systematic review.

OBJECTIVE To assess the accuracy and effectiveness of the screening of all newborn infants for developmental dysplasia of the hip (DDH) using ultrasound imaging, as is standard practice in some European countries but not in the United Kingdom, the United States, or Scandinavia. DESIGN Systematic review. DATA SOURCES Twenty three medical, economic, and grey literature databases (to March 200...

متن کامل

Comparing results of clinical versus ultrasonographic examination in developmental dysplasia of hip

BACKGROUND Developmental dysplasia of hip (DDH) is one of the congenital anomalies in newborns that if not diagnosed and treated on time can lead to a severe disability. Although clinical examination is a very useful way for screening, but in some patients, a confirmatory diagnostic method such as ultrasonography is needed. The aim of the present study is to compare the sensitivity and specific...

متن کامل

Developmental Dysplasia of the Hip: Optimal Ultrasound Screening Strategy Among High Risk Newborns

Musculoskeletal ultrasonography is becoming an attractive imaging modality for screening of high risk infants for DDH because of its advantages such as accessibility, low cost, rapid examination and ability to detect the soft tissues & cartilage which cannot be seen by conventional radiography. Hip ultrasonography has the ability not only to visualise the unossified parts of the newborn hip but...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010